For safety, instruments and accessories must be used in accordance with the operating instructions. If the instruments or 
accessories are used in a manner not specified in the operating instructions, the protection provided by the equipment may be 
impaired. 

Do not exceed the maximum signal levels of the instruments and accessories. Maximum signal levels are defined in the 
specifications and operating information and shown on the instrument panels, test fixture panels, and switching cards. 

When fuses are used in a product, replace with the same type and rating for continued protection against fire hazard. 

Chassis connections must only be used as shield connections for measuring circuits, NOT as protective earth (safety ground) 
connections. 

If you are using a test fixture, keep the lid closed while power is applied to the device under test. Safe operation requires the use 
of a lid interlock. 

If a 

 screw is present, connect it to protective earth (safety ground) using the wire recommended in the user documentation. 

The 

 symbol on an instrument means caution, risk of danger. The user must refer to the operating instructions located in the 

user documentation in all cases where the symbol is marked on the instrument. 

The 

 symbol on an instrument means caution, risk of electric shock. Use standard safety precautions to avoid personal 

contact with these voltages. 

The 

  symbol on an instrument shows that the surface may be hot. Avoid personal contact to prevent burns. 

The 

 symbol indicates a connection terminal to the equipment frame. 

If this 

 symbol is on a product, it indicates that mercury is present in the display lamp. Please note that the lamp must be 

properly disposed of according to federal, state, and local laws. 

The 

WARNING

 heading in the user documentation explains dangers that might result in personal injury or death. Always read 

the associated information very carefully before performing the indicated procedure. 

The 

CAUTION

 heading in the user documentation explains hazards that could damage the instrument. Such damage may 

invalidate the warranty. 

Instrumentation and accessories shall not be connected to humans. 

Before performing any maintenance, disconnect the line cord and all test cables. 

To maintain protection from electric shock and fire, replacement components in mains circuits — including the power 
transformer, test leads, and input jacks — must be purchased from Keithley Instruments. Standard fuses with applicable national 
safety approvals may be used if the rating and type are the same. The detachable mains power cord provided with the 
instrument may only be replaced with a similarly rated power cord. Other components that are not safety-related may be 
purchased from other suppliers as long as they are equivalent to the original component (note that selected parts should be 
purchased only through Keithley Instruments to maintain accuracy and functionality of the product). If you are unsure about the 
applicability of a replacement component, call a Keithley Instruments office for information. 

Unless otherwise noted in product-specific literature, Keithley instruments are designed to operate indoors only, in the following 
environment: Altitude at or below 2,000 m (6,562 ft); temperature 0 °C to 50 °C (32 °F to 122 °F) ; and pollution degree 1 or 2. 

To clean an instrument, use a damp cloth or mild, water-based cleaner. Clean the exterior of the instrument only. Do not apply 
cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with 
no case or chassis (e.g., a data acquisition board for installation into a computer) should never require cleaning if handled 
according to instructions. If the board becomes contaminated and operation is affected, the board should be returned to the 
factory for proper cleaning/servicing. 

Safety precaution revision as of March 2016. 

 

Содержание 3390

Страница 1: ...Verification and Adjustment Manual 3390 905 01 Rev B May 2016 P3390 905 01B 3390 905 01 www tek com keithley Model 3390 50 MHz Arbitrary Waveform Function Generator A Greater Measure of Confidence...

Страница 2: ...copy or use of the information herein in whole or in part without the prior written approval of Keithley Instruments is strictly prohibited All Keithley Instruments product names are trademarks or reg...

Страница 3: ...be connected to mains These instruments will be marked as category II or higher Unless explicitly allowed in the specifications operating manual and instrument labels do not connect any instrument to...

Страница 4: ...ways read the associated information very carefully before performing the indicated procedure The CAUTION heading in the user documentation explains hazards that could damage the instrument Such damag...

Страница 5: ...verification worksheet 1 4 Internal timebase verification 1 5 AC amplitude verification for high impedance 1 6 Low frequency flatness verification 1 7 Checking 0 dB range flatness 1 8 Checking 10 dB r...

Страница 6: ...until the next adjustment is performed Nonvolatile FLASH calibration memory does not change when power has been off or after a remote interface reset Verification interval The instrument should be ver...

Страница 7: ...pm Keysight E4418B Power meter 100 KHz to 100 MHz 1 W to 100 mW 30 dBm to 20 dBm Accuracy 0 02 dB resolution 0 01 dB Keysight 8482A Power sensor 100 KHz to 100 MHz 1 W to 100 mW 30 dBm to 20 dBm Cable...

Страница 8: ...fter acceptance If the instrument fails performance verification adjustment or repair is required Amplitude and flatness verification procedures Measurements taken during the AC amplitude high impedan...

Страница 9: ...1 KHz_20dB_reference_dBm 10 log 5 0 x 1KHz_20dB_reference2 dBm Enter the following measurements 100 KHz_0dB_reference VRMS 100 KHz_10dB_reference VRMS 100 KHz_20dB_reference VRMS Calculation of the d...

Страница 10: ...counter as shown below the frequency counter input should be terminated at 50 Figure 1 Frequency counter connection 2 Set the instrument to the output found in the table below and measure the output f...

Страница 11: ...ev B May 2016 AC amplitude verification for high impedance This procedure checks the AC amplitude output accuracy at a frequency of 1 kHz and establishes reference measurements for the higher frequenc...

Страница 12: ...shown in the table Low frequency flatness verification This procedure checks the AC amplitude flatness at 100 KHz using the reference measurements recorded in the Amplitude and Flatness Verification...

Страница 13: ...on Generator Verification and Adjustment Manual 1 8 3390 905 01Rev B May 2016 Checking 0 dB range flatness This test checks the high frequency AC amplitude flatness above 100 KHz on the 0 dB attenuato...

Страница 14: ...specification relative to 1 KHz 100 KHz_0dB_offset is calculated on the Amplitude and Flatness Verification Worksheet 5 Set the 3390 to each output described in the following table and measure the ou...

Страница 15: ...lculated This sets the power meter to read the flatness error specification relative to 1 kHz 100kHz_10dB_offset is calculated on the Amplitude and Flatness Verification Worksheet 6 Set the 3390 to ea...

Страница 16: ...3390 905 01Rev B May 2016 1 11 Checking 20 db range flatness This procedure checks the high frequency AC amplitude flatness above 100 kHz on the 20 dB attenuator range Flatness is relative to 1 kHz 1...

Страница 17: ...pecification relative to 1 kHz 100kHz_20dB_offset is calculated on the Amplitude and Flatness Verification Worksheet 6 Set the 3390 to each output described in the table below and measure the output a...

Страница 18: ...Factory Reset RST command or Instrument Preset SYSTem PRESet command In the event that the initial security code KY3390 has been changed and the new security code word has been lost use the master se...

Страница 19: ...fication procedure and verification item adjustment tests 1 self test 2 2 5 Freq_10MHz less more near true 3 ADC_2V 4 Self Cal Vos SinVos SqrVos VosOneV SqrZero SqrTwoV 5 8 27 AC Ampl 8 11 SinZero Sin...

Страница 20: ...ed equipment Brand Equipment Description Qty Keysight 3458A 8 1 2 Digit Multimeter 1 Keysight 53132A Universal counter 1 Keysight E4418B Power meter 1 Keysight 8482A Power sensor 1 BNC cable 2 BNC 1 B...

Страница 21: ...cedures 3390 50 kHz Arbitrary Waveform Function Generator Verification and Adjustment Manual 1 16 3390 905 01Rev B May 2016 ManualAdjustment exe Software interface introduction Figure 6 ManualAdjustme...

Страница 22: ...of the required instruments are set Zero Cal Power sensor calibration Connect the power sensor to the POWER REF of E4418B and then execute Begin Execute the manual calibration Address Show the addres...

Страница 23: ...n attenuator or special power head to measure the 20 dB output The default security code uses Model Name the first letter must be an alphabetic character If the first letter of Model Name is not alpha...

Страница 24: ...edures 3390 905 01Rev B May 2016 1 19 3 An error message will display as shown below during an calibration error Figure 10 ManualAdjustment exe calibration error occur box 4 If Secure AWG after calibr...

Страница 25: ...operty of Keithley Instruments All other trademarks and trade names are the property of their respective companies Keithley Instruments Corporate Headquarters 28775 Aurora Road Cleveland Ohio 44139 44...

Отзывы: