Calibrating to Achieve Correct Double Seam Specification
Ensure that the correct chuck for your particular can end is installed and tightened onto the
drive shaft.
Start by unplugging the Cannular machine from the power supply. The rollers can be
adjusted with the top cover on; however, it may make it easier to access the adjustment
nuts with the top cover removed as shown below:
Bottom Die (Turn Table) Height Adjustment
Using an allen key or a steel rod undo the coupling nut on the base of the turn table
support. Turn the allen or steel rod clockwise to undo the coupling nut. You can apply force
in the opposite direction to the lever to prevent it rotating as you undo the coupling nut.
Turn the table support counter-clockwise to raise and clockwise to lower the turn table
support.
Place a can with a lid into the machine and twist the lever to raise the table to the maximum
height.
Gradually raise the turn table support by rotating it in a counter-clockwise direction until
firm pressure holds the can against the chuck. The can should be held firmly in place but
Left: Loosening coupling nut Right: Tightening coupling nut