Cannular Semi-Auto Instruction Manual
Page
14
of
23
www.KegLand.com.au
Last Updated 24/04/2020 5:59 PM
2
nd
Op Roll Height and Gap Adjustment
The left roller undertakes the 2
nd
Operation on the Semi-Automatic Cannular.
Similarly to setting up the 1
st
op roll height and gap do the same thing with the 2
nd
Op roll,
ensuring that adjustments are made when the 2
nd
Op roll is at its closest position to the
chuck.
The gap “Y” on the 2
nd
Op Roll should be 1.2 – 1.3 mm
The gap “X” on the 2
nd
Op Roll should be 0.3 – 0.4 mm
Check Your Roll’s Spin
In order for the Cannular canning machine to work efficiently the rolls must be able to spin.
Ensure the Allen key bolts on the underside of the rolls are done up tightly but once you
have done this, rotate the rolls with your finger to ensure they can still turn without much
resistance.