The second op seam thickness is quite
easy to measure using calipers.
Using Can B, take the average of 4
measurements around the
circumference of the can. The average
of these 4 measurements should be
between 1.2-1.3mm.
If your measurement is smaller than this
range you might find that you have
applied too much force with the second
roller or maybe you have not achieved
sufficient actual overlap. You should re-
examine the actual overlap again.
If your measurement is too large you may not have applied enough force on the lever in
operation 2.
CAN B