PROBLEM SOLVING
Mirage technical manual
page 54 of 65
VAC can be measured
at the “entrance” of the controller (the red wire on position 12 of the large green
plug in the controller). When the transformer breaks down, the entire controller should be replaced.
Replace controller
Different versions of controllers are used in the Mirage which are not always compatible. When
installing a new controller, make sure that you have the correct replacement. A new controller (the so-
called LL
√
version, see Figure P 1) ordered from KvdW will have an installation leaflet to set different
functions according to machine model.
Figure P 1a (left). Model tag of the LL
√
version of the Gicar controller. It is identified by the "PUMP 2"
indication above-left.
Figure P 1b (right). Cover taken from controller. 12-pole green connector on bottom, 7-pole connector
above.
1. Turn mains switch to "0".
2. Remove right side panel.
3. Remove top of controller cover by pushing the lateral snaps inwards while pulling the cover from
its base.
4. Unplug all electrical connectors.
5. Either remove the card together with base by removing the 4 Philips screws from the base or
remove only the card by removing it from the 4 self-blocking columns in the cover base.
6. Mount the new controller, either with base or just the card. When the base was removed as well,
make sure that the wiring is positioned correctly behind the base.
7. Remount all electrical plugs, they only fit in one position.
8. Replace controller cover.
9.
Turn machine “on” and check for proper operation.
10. Remount side panel.