PROBLEM SOLVING
Mirage technical manual
page 60 of 65
connector block. If the no.1 connector on the SSR does not show mains voltage, the SSR is failing
and has to be replaced.
Problem solving
1. First verify if safety overheating switch has not been activated (single-phase machines only):
Turn mains switch
to “0”, remove left hand side panel, press red button on safety overheating
switch
1
, turn mains switch
to “2”, check functioning of machine.
If that did not have the desired result:
2. Turn mains switch
to “0”.
3. Check fuse(s), then check machines' functioning.
If no result:
4. Replace the SSR (see above).
5. Turn mains switch
to “2”.
6. Check functioning of machine.
7. Remount side panel.
1
When the machine has actually overheated, it must cool down to appr. 105
°
C before the overheat
safety switch can be re-set.