MAINTENANCE MANUAL
Mirage technical manual
page 31 of 65
9. When remounting the flange valve, make sure that both Viton sealing O-rings are properly
mounted on/in the valve base and that the holes in the valve base line up with the holes in the
mix-block. Use new locking washers, do not over tighten the 4 Phillips bolts.
10. Remount the solenoid coil with spring washer and nut. The spring washer should be nearly flat but
not over tightened as this will result in damage to the valve.
11. Remount cup warmer (put grease on Allen bolts).
12. Open water mains.