background image

KC-P30 x-series

Functions

Configuration manual V4.09

29

© KEBA

5

Functions

The following chapters describe special functions of the charging station.

5.1

Load management in the local charging network

Load management in a local charging network allows multiple KeContact
charging stations to operate on a common supply. The maximum power al-
lowed by the supply line is divided by the master charging station.

Information

Charging at a slave charging station is only possible if there is a connection
to the master charging station. This prevents overloading of the connection.

5.1.1

Equal allocation mode

If the parallel active charging stations in a local charging network request
more power than the power supply provides (set maximum current), the
available charging current is divided evenly across all charging sessions.

Charging current per charging station = set maximum current per
phase / number of active charging sessions on this phase

If insufficient power is available for an additional charging process in the
charging network (set minimum current is underrun), the new charging
process will be lined up. Every 15 minutes, an active charging session is
paused in sequence, lined up at the back of the line, and the next charging
session in the line continues.

5.1.2

Current limiting

The current limiting for the charging station can be regulated in various
ways.

Setting by means of DIP switches locally on each charging station

Specification by master charging station

Specification via UDP connection

Reading out an external meter using Modbus TCP

If a current limit is specified via several different types, then the lowest preset
value is used for the currently valid current limit.

5.1.3

Phase-related load management

Phase-related load management is used for a charging network with charg-
ing stations with a 3-phase connection.

Содержание KeContact X Series

Страница 1: ...KeContact KC P30 x series Charging Station Configuration manual V 4 09 Translation of the original instructions...

Страница 2: ...due to further technical developments Details presented may be subject to correction All rights reserved KEBA AG Headquarters Gewerbepark Urfahr 4041 Linz Austria 43 732 7090 0 kecontact keba com www...

Страница 3: ...Design of a local charging network master slave 13 3 Configuration 16 3 1 Connection panel 16 3 2 DIP switch settings 16 3 3 Enabling the DHCP server 17 3 4 Configuration in series via USB stick 17 4...

Страница 4: ...e The device variant can be determined by the product designation on the type plate The software version can be read out via the web interface For more information see the operating instructions The p...

Страница 5: ...lly hazardous situation which can result in death or seri ous bodily injury if the corresponding precautions are not taken CAUTION means that if the corresponding safety measures are not taken a poten...

Страница 6: ...hazards Knowledge of current valid safety information the mode of operation of the charging station the displays and operating elements of the charging station basics of network technology basics of I...

Страница 7: ...n by the specialist dealer or service partner must be ini tiated 1 5 Notes on this document The manual is part of the product It is to be retained over the entire life cycle of the product and should...

Страница 8: ...on Manuals and additional information are available on our website www keba com emobility downloads Designation Target group Operating instructions End customer Electrician Installation manual Electri...

Страница 9: ...itch 3 Master charging station x series 4 Slave charging station c series 5 Higher level network Internet 6 OCPP backend Only P30 x series can be operated as master charging stations only P20 P30 c se...

Страница 10: ...t1 Anschluss LSA Via the LAN interface P30 x series can also be connected to other charging stations whereby a charging network can be realized Information The Ethernet2 connection X3 RJ45 is for diag...

Страница 11: ...nnection to an OCPP backend can be made 1 P30 x series 2 Router 3 Internet 4 OCPP backend The technical data of the WLAN module can be found in the Installation Manual Information Only a charging stat...

Страница 12: ...ich is en closed with the mounting material The following steps are necessary to perform the configuration via a mobile device 1 Connect a mobile device to the WLAN access point 2 Access the IP addres...

Страница 13: ...cal charging network is implemented differently 1 slave charging station Direct connection The slave charging station is connected directly to the master charging station Multiple slave charging stati...

Страница 14: ...is case the master charging station must be configured as a DHCP server The IP address is then assigned to the slave charging station by the master charging station 2 2 3 Connection via router or swit...

Страница 15: ...ion 2 2 4 Ports for communication in the charging network For the correct communication in the charging network the ports below must be enabled network internally Information If necessary contact your...

Страница 16: ...the housing cover and the connection panel cover must be removed The description of removing the covers and the connection panel can be found in the Installa tion Manual 3 2 DIP switch settings This...

Страница 17: ...ion is deactivated in the deliv ery state and can be activated via configuration via USB stick or in the web interface 3 4 Configuration in series via USB stick Several P30 x series can be configured...

Страница 18: ...stick to additional charging stations 3 4 2 Read out configuration In order to be able to transfer the configuration of one P30 x series to addi tional P30 x series the USB stick must be connected to...

Страница 19: ...urations that only apply to one charging station must be adapted or deleted in the configuration file All settings are listed in the configuration file The figure below shows a sec tion of a configura...

Страница 20: ...guration can be adapted manually Each of the listed settings can be adapted by editing the value to the right of the equal sign Example of a possible adaptation of the configuration Initial configurat...

Страница 21: ...integrated DHCP server The charging station automatically receives an IP address via the DHCP server of the router The IP address is displayed on the charging station display when the charging statio...

Страница 22: ...irectly in the web interface next to the respective configuration entry The actual size of the web interface may differ depending on the device vari ant 4 1 Main menu The main menu is divided into the...

Страница 23: ...he charging plug is unlocked Network Connection Here information about the network interfaces LAN mobile communica tions WLAN and WLAN Access Point of the master charging station is dis played Backend...

Страница 24: ...ere DSW Settings The DIP switch settings of each charging station in the charging network can be displayed here Factory Data Reset The Reset button resets the configuration of the charging station to...

Страница 25: ...station is operated as a single charging station or as a master charging station in a charging network The number of slaves must be entered for a charging network In addition all attached slave chargi...

Страница 26: ...lure This setting is disabled by default Chargepoint Parameters The connection type 1 phase or 3 phase of the charging station is selected here For a 1 phase connection the power cable wire that is us...

Страница 27: ...rea Display Text Here you can make settings for the text that is shown on the display de scribing various processes of the charging station The language of the text can be changed the display duration...

Страница 28: ...technician to access the charging station via an encrypted connection These settings can also be configured on the OCPP backend Log Level For error diagnosis it can be necessary to record the operatio...

Страница 29: ...ons Charging current per charging station set maximum current per phase number of active charging sessions on this phase If insufficient power is available for an additional charging process in the ch...

Страница 30: ...cards can be stored It is not possible to teach in the RFID cards directly at a charging station The first 1000 RFID cards are relayed from the OCPP backend to the master charging station where they a...

Страница 31: ...is not possible for a connection failure 5 2 2 Displays and signals During RFID authorization the charging station can display different light patterns on the LED bar and emit acoustic signals LED ba...

Страница 32: ...ont of the RFID reader A successful teach in process is confirmed by a rising tone sequence Teaching in a slave RFID card 1 Hold the master RFID card in front of the RFID reader and wait for the risin...

Страница 33: ...n in the web interface to ON Each authorization request is relayed to the OCPP backend Authorization in the web interface to OFF A charging process can only be started without holding up an RFID card...

Страница 34: ...acturer or sup plier The following OCPP versions are supported OCPP 1 5 via SOAP OCPP 1 6 via SOAP or JSON Connection to an OCPP backend When connecting to an OCPP backend note the following It is rec...

Страница 35: ...ackend can be reached 123 UDP Incoming and outgoing Port for the time server of the charging station Supported messages The following table provides an overview of the supported messages Message OCPP...

Страница 36: ...external meters The charging station can read out the measured values from external meters via Modbus TCP This allows an intelligent calculation of the charging cur rent provided to the vehicle and t...

Страница 37: ...by the DIP switches to regulate the charging current so that the maximum energy supply never exceeds the am perage of the post meter circuit breaker for configuring the DIP switches see 5 5 3 Settings...

Страница 38: ...ether you have a single charging station or a charging network Configuration for a single charging station The post meter circuit breaker is designed for a certain amperage To en sure that the chargin...

Страница 39: ...Configuration for a charging network For a charging network the maximum permitted charging current per phase and the maximum permitted charging capacity for the entire charging net work can be config...

Страница 40: ...vehicle is plugged in at the charging station Information The software update can take up to an hour The update process is indi cated by a slow orange flashing of the LED bar After the software updat...

Страница 41: ...be activated in the configuration web interface To perform a software update via a USB stick proceed as follows 1 Download the current software for the charging station keb file 2 Plug the USB stick...

Страница 42: ...ic connection monitoring 37 Settings 38 External meters Connection 37 Supported meters 37 L LAN 10 Load management 29 M Master charging station 13 Mobile communications 12 Modbus TCP 36 N Network inte...

Отзывы: