KC-P30 x-series
Web interface
Configuration manual V4.09
26
© KEBA
Device
The basic settings for the charging station are configured here:
Managing the authorization function (see
chronize time of the charging station with the time of the browser (the charg-
ing station restarts after a time synchronization); activating and deactivating
the USB stick functions.
Charging Network Parameters
The nominal supply voltage of the charging station is selected here and the
current limits for the charging network can be set.
With 1- or 2-phase charging vehicles, asymmetrical loading of the 3 phases
may occur. For such vehicles, the maximum charging current can be set in
this area. The charging station then detects whether the vehicle is a 1-, 2- or
3-phase charging vehicle and, if necessary, reduces the charging current to
the set value. If "0" is entered, this function is deactivated.
You can also set whether charging should continue after a power failure.
This setting is disabled by default.
Chargepoint Parameters
The connection type (1-phase or 3-phase) of the charging station is selected
here. For a 1-phase connection, the power cable wire that is used can also
be selected. For a charging network, the connection type of the slave charg-
ing stations can also be selected.
If a slave charging station loses the connection to the master charging sta-
tion, or if an error occurs at the master charging station, a specification can
be made for the maximum charging current at which charging is to be contin-
ued. If "0" is entered, the charging process is terminated in the event of an
error and the charging station is put into "out of operation" mode.
Network Connection
The network communication can be selected and configured here.
Certificates
Certificates in
*.pfx
format can be imported for an encrypted connection.
The connection to the web interface, to the OCPP backend and to the charg-
ing station can be encrypted. The following certificates are available:
Certificate
Encrypted
connection to ...
Required key
Https WebUI
Web interface
Private key
OCPP Server
OCPP backend
Private key
OCPP Client
Charging station
Public key