M20
Functions
V1.02
47
© KEBA 2022
Eingabe
Beschreibung
Expiry Date
Date up to which the RFID card is to be valid.
Master RFID Card
Set the RFID card as master RFID card. Only one card can be
defined as master RFID card.
Status
Authorization of the RFID card. Here it is also possible to block
an RFID card and thus prevent charging with the relevant RFID
card.
Charging Station –
Serial No.
Serial number of the charging station where the RFID card may
be authorized. All or only certain charging stations in the charg-
ing network can be enabled for the RFID card.
9.2.3
RFID authorization with OCPP backend connection
If the charging station or a charging network is controlled by an OCPP back-
end, please note the following:
●
Teach in RFID cards:
All RFID cards must be "centrally taught in" at the OCPP backend.
●
"Authorization" in the web interface to "ON":
Each authorization request is relayed to the OCPP backend.
●
"Authorization" in the web interface to "OFF":
A charging process can only be started without holding up an RFID card
if the predefined token set in the configuration is recognized and ac-
cepted by the OCPP backend.
Information
For information on the functionality and the required settings of the OCPP
backend, refer to the specific manual of the system used.
9.3
OCPP backend
The charging station offers the option of being connected to a central man-
agement system via the Open Charge Point Protocol (OCPP). OCPP, as an
open application protocol, makes it possible to connect any central manage-
ment system to the charging station regardless of the manufacturer or sup-
plier. The following OCPP versions are supported:
●
OCPP 1.5 via SOAP
●
OCPP 1.6 via SOAP or JSON
Connection to an OCPP backend
When connecting to an OCPP backend, note the following:
●
It is recommended that the master in the network be assigned a static IP
address based on the MAC address of the device.
●
Since the OCPP backend is usually not in the same network, the charg-
ing station must be assigned a "public IP address" which is routed to the
internal IP address (NAT).
Содержание KeContact M20
Страница 63: ......
Страница 64: ...KEBA Energy Automation GmbH Reindlstraße 51 4040 Linz Austria www keba com ...