Chargepoint parameters
No. of charging stations
The number of connected client charging stations is configured and the cur-
rent limits for the charging network are also set here. Depending on the
product variant, up to 200 client charging stations can be specified.
Charging network settings
CAUTION!
Fire hazard from overload!
The configuration of the maximum current values per charging point does
not replace the short-circuit- and overload-protection of the connected
charging points. The overload- and short-circuit-protection must be imple-
mented according to the applicable installation regulations.
The maximum total available current, minimum charging current and maxi-
mum current for asymmetrical charging and the function for asymmetrical
charging of the charging group are configured here. Furthermore, the cluster
function can be activated and deactivated.
Cluster
The respective clusters can be configured, exported and imported. Max. 15
clusters can be set. A name (alias) can be assigned for each cluster. The
maximum current, phase assignment and minimum charging current are also
configured here.
Chargepoint parameters
The connection type (1-phase or 3-phase) of the charging station is selected
here. For a 1-phase connection, the power cable wire that is used can also
be selected. For a charging network, the connection type of the client charg-
ing stations can also be selected.
If a client charging station loses the connection to the master, or if an error
occurs at the master, a specification can be made for the maximum charging
current at which charging is to be continued. If "0" is entered, the charging
process is terminated in the event of an error and the charging station is put
into "out of operation" mode.
8.1.5
System
The area offers the following options:
●
Software update
●
Logging
●
DSW settings
●
Factory data reset