a) To start KEB COMBIVERT F4-F Lift Version 1.4 with an
asynchronous motor do as follows:
9.1 Inital Start-Up
Start
Parameterize inverter
(LF-parameter)
Parameter LF.30=2
(closed loop operation)
Preset drive
command with
return control
NO
YES
YES
NO
Is direction of
travel correct for
cabin ?
Improvements in
drive comfort
Exchange encoder
track (LF.18) = on ?
E.Enc ?
Exchange direction of
travel (LF.05 = 1)