ANTRIEBSTECHNIK
GB 39
GB
8. Parameter
Description
V
N
V
E
t
V
Unit:
1
Value range:
off / on
Factory setting:
off
Ogive Function
V
V
N
If the ogive function is switched off the acceleration is immediately
interrupted at the delay point.
delay point
LF. 75 = off
If the ogive function is switched on and according to the adjusted
parameters LF.77 and LF.78 the drive accelerates to the braking
distance calculated ogive speed and decelerates than to crawl drive.
After the ogive function is switched on the drive curve of the lift should
not be changed. The ogive function must be switched on again if
there is a change at the drive curve.
V
E
V
S
delay point
ogive-status
LF. 75 = on
t