ANTRIEBSTECHNIK
GB 47
GB
8. Parameter
Description
Unit:
impulse per revolution
Value range:
256 … 10000 Imp/r
Factory setting:
2048 Imp/r
Adjusted value:
in accordance with the motor name plate
SSM Encoder (inc/r)
Unit:
1
Value range:
1 … pole pair of the motor
Factory setting:
1
Adjusted value:
according to the encoder pole pair
SSM Encoder Pole Pair
LF.62 displays the position of the encoder to the rotor position of the
motor. (see also LF.b5)
The position trimming (descriped in parameter LF.b5) must not be
done if the system position of the motor and encoder is known. The
position value can be written directly in parameter LF.b2.
The inverter must switch off and on to store the
system position.
Unit:
1
Value range:
– 32768 … 32767
Factory setting:
49A4h
Adjusted value:
according to encoder position
System Position
Unit:
millihenry
Value range:
0,1 … 600,0 mH
Factory setting:
8,1 mH
Adjusted value:
in accordance with the motor name plate
Winding Inductance (L
U-V
)