ANTRIEBSTECHNIK
GB 21
GB
1
2
3
4
5
6
7
8
9
START
STOP
FUNC.
SPEED
ENTER
F/R
7. Operation
An operator is a necessary for local operation of the inverter KEB
COMBIVERT F4-F. To prevent malfunctions, the inverter must be brought
into
nOP
status (control release terminal X2.1 ).
The operator is not necessary for operating.
The operator is available in several versions:
Digital-Operator
Part.-No. 00.F4.010-2009
7.1
Digital- / Interface-
Operator
Operator panel
Operating-/Error display:
Normal "LED on"
Error "LED blinks"
5-digit LED-Display
Interface control
Display "LED flickers"
RS232/RS485
PE-Connection
Interface-Operator
Art.-Nr. 00.F4.010-1009
In the interface operator there is an additional isolated RS232/RS485-
interface integrated.
Information about other versions of operators contact KEB!
PIN RS485 Signal
Description
1
–
–
Reserved
2
–
TxD
Transmission signal/RS232
3
–
RxD
Incoming signal/RS232
4
A'
RxD-A
Incoming signal A/RS485
5
B'
RxD-B
Incoming signal B/RS485
6
–
VP
Supply voltage plus +5V (I
max
= 10 mA)
7
C/C'
DGND
Reference potential
8
A
TxD-A
Transmission signal A/RS485
9
B
TxD-B
Transmission signal B/RS485
Содержание COMBIVERT F4-F
Страница 65: ...ANTRIEBSTECHNIK...