manualshive.com logo in svg
background image

Содержание UC1122

Страница 1: ......

Страница 2: ...tus 10 4 3 General 11 4 4 LoRaWAN 13 4 4 1 Basic 13 4 4 2 Channel 15 4 4 3 Advanced 16 4 5 Command 18 4 5 1 Read Command from Device 18 4 5 2 Open a Command File 19 4 5 3 Save the Command to Device 19...

Страница 3: ...ondition brings attention to engineering personnel immediately The output can be connected with an alarm indication device such as a light or horn The module can give immediate response to the status...

Страница 4: ...CN 470 510 EU 863 870 US 902 928 AU 915 928 KR 920 923 Sensitivity 147 dBm 300bps Output Power 20dBm Protocol LoRaWAN Class C Analog Input 4 20 mA 0 5 V Optional Differential inputs 12 bit Digital Inp...

Страница 5: ...ble power supply comes with the retail product For industrial applications it is advised that the Ursalink UC1122 should be installed into its own metal housing and be powered from a separate power su...

Страница 6: ...A 3 Digital Input Opto isolated depending on voltage DC Voltage 3 24V 4 Digital Output Driving relay to connect NC or NO 3 5 Analog Input When the value of analog input exceeds or is under the predefi...

Страница 7: ...0 1 V will indicate an Input De activate state When terminal IN is connected to 3 24 V it will indicate an Input Activate state Trigger voltage Minimum 3 VDC Maximum 24 VDC 3 7 Relay Output The output...

Страница 8: ...rsalink UC1122 to PC via the micro USB cable Step 2 Power on the Ursalink UC1122 Step 3 Run the Ursalink ToolBox The software will display this interface when getting started Here you can create a new...

Страница 9: ...UC1122 User Guide 9 4 1 1 Serial Port Settings When the Ursalink ToolBox displays Connecting to device please wait You can click Serial Port Settings to set the correct serial port parameters...

Страница 10: ...to see the basic status information of this device Serial Port Settings Item Description Default Serial Port Select the serial port for data transmission Null Login Password Enter the login password...

Страница 11: ...h used for the RX2 receive window Analog1 Show the value of the Analog Input1 Format scaled output value analog input value Analog2 Show the value of the Analog Input2 Format scaled output value analo...

Страница 12: ...ll Confirm Password Enter the new password again Null The following variables are pertinent to the scaling formula Ov scaled output value Iv analog input value Osh high limit of the scale for the scal...

Страница 13: ...ed from the diagram Ov Osh Osl Iv Isl Ish Isl Osl This can be rewritten as Ov Osh Osl lsh lsl lsh lsl Osl 4 4 LoRaWAN 4 4 1 Basic Basic Settings Item Description Default Device EUI Enter the identifie...

Страница 14: ...on by Personalization Under certain circumstances end devices can be activated by personalization Activation by personalization directly ties an end device to a specific network by passing the join re...

Страница 15: ...ecific for the end device It is used by the end device to calculate the MIC or part of the MIC message integrity code of all uplink data messages to ensure data integrity 5572404c696e 6b4c6f5261323 03...

Страница 16: ...have to configure a 923 2 MHz channel on gateway as well 4 4 3 Advanced Advanced Settings Item Description Default Confirm Mode Disabled UC1122 will send uplink unconfirmed packet Enabled The last pac...

Страница 17: ...LoRaWAN Regional Parameters Join Trials The maximum number of the device to resend the join request when the device failed to join the network 0 ReTx The maximum number of the device to resend the dat...

Страница 18: ...eset to 0 0 Downlink Frame Counter The number of data frames which received by the e nd device downlink from the network server It will be incremented by the network server Users cloud reset the a per...

Страница 19: ...ned behaviour commands Each command takes the form of an IF THEN statement pair You are thus able to select certain trigger conditions to cause desired actions The Ursalink UC1122 allows up to 8 separ...

Страница 20: ...cified option The user can setup multiple combinations however digital input 1 be activated before action is taken Then the user can choose from the following options Goes active rising edge triggered...

Страница 21: ...e 3 single actions at most to be executed for a single trigger condition 4 6 1 4 IF Analog Input A statement containing this IF condition will be triggered if the analog voltage measured at the termin...

Страница 22: ...true again Note The threshold setting range is associated with ADC settings If you have set up ADC settings then threshold setting range would be Osh to Osl If you haven t setup ADC settings the thres...

Страница 23: ...me 4 6 2 2 THEN Send A Custom Message A command containing this Action will send a custom text message via LoRaWAN if the condition is met Only letter number comma period separator space and exclamati...

Страница 24: ...om the PC Step 5 Click Upgrade and the device will check if the firmware file is correct If it s correct the firmware will be imported to the device and the device will restart after upgrading is comp...

Страница 25: ...C1122 will send a custom message at 8 a m every Monday 5 2 Control Appliances 5 2 1 Control a Bulb by Sending a Message In this case we need to turn on or off a 220 V light bulb via a suitable LoRa me...

Страница 26: ...UC1122 User Guide 26 Configuration 5 2 2 Turn on the Heater Regularly Configuration Hardware Software...

Страница 27: ...UC1122 User Guide 27 5 2 3 Send an Alert When Over temperature Occurs Configuration Hardware Software END...

Отзывы: