![KEB COMBIVERT F4-C Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/keb/combivert-f4-c/combivert-f4-c_applications-manual_3852415086.webp)
6
1
Name: Basis
KEB COMBIVERT F4-C
16
09.04.99
©
KEB Antriebstechnik, 1999
All Rights reserved
Functional Description
Chapter
Section
Page
Date
Operating and Appliance Displays
Adr.
min
max
default
Adr.
min
max
default
2C01h
0,1
A
LTK
460
0
6.1.5 Description of In-Parameters
2C00h
In. 0
Inverter type
1
hex
-
-
-
The inverter type is indicated in hexadecimal numbers. The bits have following meaning:
bit 0:
Voltage class
0 = 200V
1 = 400V
bit 1-5
Unit size
05,07,09,....
bit 6-9
Control type
0 = 0A.F4 ( F4-C / up to housing size E )
1 = 0B.F4 ( F4-S / up to housing size E )
2 = 00.F4 ( F4-C / from housing size G upwards)
bit 10-12
Rated operating frequency
0 = 2kHz
1 = 4kHz
2 = 6kHz
3 = 8kHz
4 = 10kHz
5 = 12kHz
6 = 14kHz
7 = 16kHz
bit 13-15
Maximal operating frequency
0 = 2kHz
1 = 4kHz
2 = 6kHz
3 = 8kHz
4 = 10kHz
5 = 12kHz
6 = 14kHz
7 = 16kHz
Example:
hex
F
C
9
D
binary
1 1 1 1 1 1 0 0 1 0
0 1 1 1
0 1
decimal
7
7
2
14
1
=>
14.F4.C 16 / 16kHz 400V
In. 1
Rated inverter current
Display of rated inverter current in A. The value is determined from the power circuit identification (LTK) and cannot be
changed.