Operating and Appliance Displays
Adr.
min
max
default
Adr.
min
max
default
Adr.
min
max
default
ud.11
!ud.11!
ud.11
!ud.11!
202Dh
ru.45 Display analog option
0,1
%
-
100
-100
This parameter displays the percentual value of the signal at the optional analog input.
-10V...0...+10V = -100%...0...100%
202Eh
ru.46 Ramp output frequency
0,0125
Hz
-
409,58
-409,58
This parameter displays the frequency at the output of the ramp generator. If the internal PI-controller is not active, the
displayed frequency corresponds to the output frequency ru.3.
202Fh
ru.47 Actual frequency encoder
0,0125
Hz
-
409,58
-409,58
The displayed value depends on cn.3.
cn.3 = 0 (default)
The actual frequency of ru.3 is displayed.
cn.3 = 1 or 2
The current actual frequency of the encoder interface (option) is displayed. This measured value
corresponds to the real slip-afflicted actual speed.
1: channel 1
2: channel 2
A counter-clockwise rotating field (reverse) is represented by a negative sign. Precondition is the correct phase connection
of the motor.
For a closed-loop-controlled system it is imperative to ensure the correct correct phase connection, otherwise
the controllers would run into their limit.