![KEB COMBIVERT F4-C Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/keb/combivert-f4-c/combivert-f4-c_applications-manual_3852415022.webp)
2
1
KEB COMBIVERT F4-C
6
Name: Basis
09.04.99
©
KEB Antriebstechnik, 1999
All Rights reserved
Product Description
Summary
Chapter
Section
Page
Date
2.1.6
Unit Sizes 230V-Class
The following technical specifications refer to 2-/4-pole standard motors. In case of
different pole numbers the frequency inverter must be dimensioned for the rated
motor current. With regard to special or medium frequency motors, please contact
KEB.
The power losses always refer to the max. switching frequency. If the switching
frequency is reduced, the power loss is reduced as well.
Site altitude max. 2000 m. For altitudes of 1000 m or more above N.N. a power reduction
of 1 % per 100m must be taken into account.
2.1.5
Validity of
Specifications
1)
This data is only valid for units with internal brake transistor (see „2.1.4 Type Code“).
Inverter Size
07
09
10
13
14
15
16
Output nominal power
[kVA]
1,6
2,8
4
8,3
11
17
23
Max. rated motor power
[kW]
0,75
1,5
2,2
5,5
7,5
11
15
Output nominal current
[A]
4
7
10
24
33
48
66
Max. short-time current
[A]
7,2
12,6
18
36,5
49,5
72
99
OC-tripping current
[A]
8,8
15
22
43
59
88
119
Nominal input current
[A]
8
4,4
14
7,7
20
11
26,5
36
53
73
Housing size
D
D
D
D
D
D
E
G
G
H
H
Rated operating frequency
[kHz]
16
8
16
4
16
16
16
16
Max.operating frequency
[kHz]
16
8
16
4
16
16
16
16
Power loss at nominal operating
[W]
65
70
135
165
220
280
430
550
Max. heat sink temperatureT
OH
[°C]
85
85
85
73
90
90
90
90
Max. permissible mains fuse (inert)
[A]
20
10
20
10
25
20
35
50
80
80
Line cross section
[mm²]
2,5
1,5
2,5
1,5
4
2,5
6
10
25
25
Min. braking resistor
1)
[
Ω
]
56
56
28
39
16
13
5,6
5,6
Typ. braking resistor
1)
[
Ω
]
100
100
68
56
22
16
13,6
8,8
Max. braking current
[A]
7
7
14
21
29
29
70
70
Tightening torque for terminals
[Nm]
0,5
1,2
Mains voltage
[V]
180...260 +/-0 (230V Nominal voltage)
Phases
1
3
1
3
1
3
3
3
3
3
3
Mains frequency
[Hz]
50 / 60 +/- 2
Output voltage
[V]
3 x 0...U Mains
Output frequency
[Hz]
see control board
Shielded motor line length
[m]
30
30
50
50
100
Storage temperature
[°C]
-25...70 °C
Operating temperature
[°C]
-10...45 °C
Model / protective system
IP20
Relative humidity
max. 95% without condensation
Tested in accordance with...
EN 61800-3
Climatic category
3K3 in accordance with EN 50178