KEB COMBIVERT F4-C
8
Name: Basis
30.01.98
Functional Description
PI-Controller
©
KEB Antriebstechnik, 1997
All Rights reserved
Chapter
Section
Page
Date
100%
0%
cn.10
cn.11
cn.10 Minimum frequency= 0,0...409,5875 Hz
cn.11 Maximum frequency = 0,0...409,5875 Hz
The adding set value can be influenced by an adjustable function Out%=f(In%) in
cn.13. At cn.13 = „1 or 2“ the max. Out%-Value is determined with cn.14. Following
adjustments are possible:
cn.13
Function
0
Out% = In% (linear without limitation)
1
Out% = (In% / 100%) · cn.14 (linear with limitation to cn.14)
2
Out% = (In% / 100%)² · cn.14 (parabolic with limitation to cn.14)
3
Out% = -In% (linear inverted without limitation )
Picture 6.11.4
Adding set value function
cn.13, cn.14