KCI V.A.C. ATS Скачать руководство пользователя страница 32

V.A.C.

 ATS Operations and Maintenance Manual 

 

28 

 
 
 
 

PART DESCRIPTION 

KCI PART NO. 

IV POLE CLAMP ASSEMBLY 

6244807 

IV POLE CLAMP - END CAP FRICTION PAD 

3256013 

MANIFOLD  

3254220 

CANISTER HOLDER ASSEMBLY 

6251306 

TUBE ASSEMBLY (SMALL BELLOWS) 

6264476 

TUBE ASSEMBLY (LARGE BELLOWS) 

6264477 

SOLENOID VALVE ASSEMBLY 

6264526 

WIRE ASSEMBLY- LED TO POWER SUPPLY BOARD 

6265390 

WIRE ASSEMBLY- INLET SWITCH TO POWER SUPPLY BOARD 

6265391 

TOUCHSCREEN WINDOW 

3256204 

REAR HOUSING ASSY - SPARES ONLY NUMBER 

6268523 

FRONT HOUSING ASSEMBLY 

6268521 

CANISTER PCB 

6271139 

BATTERY 

4270547 

CONTROLLER PCB 

6271138 

VACUUM PUMP 

6257756 

POWER SUPPLY / CHARGER BOARD 

6271140 

PUMP RETAINING BRACKET 

3243308 

REAR CHASSIS PLATE 

3244713 

10 WAY RIBBON CABLE 

6243829 

8 WAY RIBBON CABLE 

6243828 

SCREEN CHASSIS 

3243307 

SCREW - M3X16 BUTTON HEAD 

7259183 

SCREW - M4X8 PAN HEAD CW S/PROOF WASHER 

7259185 

SCREW - M3X6 PAN HEAD CW S/PROOF WASHER 

7259184 

BATTERY RETAINING BRK ASSEMBLY 

6243115 

SWITCH PROTECTOR 

3258420 

GREEN L.E.D WIRE ASSEMBLY 

6265390 

SWITCH / INLET 

4268833 

CANISTER LATCH 

3266221 

SCREW - M4X12 PAN HEAD CW S/PROOF WASHER 

7259187 

MAINS CORD (USA) 

4268840 

MAINS CORD (SHUKO) 

4268742 

MAINS CORD (UK) 

4268743 

SECONDARY FILTER  

6248806 

LARGE BELLOWS 

4242002 

POWER CORD RETAINING CLIP 

3262615 

MANUAL (ENGLISH) 

6252203 

SCREW - COUNTERSUNK M3 X 8MM 

7259182 

FILTER SPRING 

3262613 

SCREW M4 X 12MM 

7259187 

PIN - HANGER ARM - LARGE 

3256524 

DISPLAY AND TOUCH PANEL ASSEMBLY 

6270514 

ACTUATOR TONGUE 

3266222 

BATTERY FOAM SPACER 

3249365 

IV FRICTION PAD 

3256009 

BATTERY HISTORY LABEL 

5964 

 

SPARES LIST 

 

RESTRICTED USE 

Certain pages of this manual are designated 

“Restricted Use Only.” Information contained on 

those designated pages may be used solely to 

facilitate the proper maintenance and repair of 

KCI products identified herein. If these terms are 

unacceptable, immediately remove those 

designated pages and return them to KCI, Attn: 

Legal Dept. Refer to qualified service personnel 

who are authorized by KCI for proper 
maintenance and repair

 

Содержание V.A.C. ATS

Страница 1: ...ormation contained on those designated pages may be used solely to facilitate the proper maintenance and repair of KCI products identified herein If these terms are unacceptable immediately remove tho...

Страница 2: ...s of the equipment designated by the manufacturer as repairable Although this equipment conforms to the intent of the directive 89 336 EEC in relation to Electromagnetic Compatibility all electrical e...

Страница 3: ...tinuous or Intermittent Therapy 6 Intensity Level 6 Lockout Feature 7 Applying the Dressing 8 Canister Installation Removal 9 Disposal of Used Dressings and Canisters 10 Alarms 11 Canister full 11 Tub...

Страница 4: ...V A C ATS Operations and Maintenance Manual iii Specifications 30 Explanation of Symbols Used 31 Ordering Information 32 Contact addresses 32...

Страница 5: ...r organs Precautions Always Follow Universal Precautions Precautions should be taken with patients exhibiting active bleeding difficult wound hemostasis or who are on anticoagulants When placing the V...

Страница 6: ...und Consider placing a single layer wide meshed non adherent dressing prior to foam placement DISCOMFORT If patient complains of discomfort throughout therapy consider changing to white PVA Versa Foam...

Страница 7: ...y switches to battery power when AC mains power is removed Extended Pump Life Linear brushless pump with increased life expectancy Intensity Setting The speed at which the target pressure setting is a...

Страница 8: ...upright position CAUTION The IV Pole Clamp should only be used on poles that are in excess of 2 2cm 9 diameter and are securely attached to a bed frame or a stable stand To ensure stability of the the...

Страница 9: ...therapy levels between 50 and 200mmHg as per physician order The therapy unit is set at a standard negative pressure of 125mmHg OPERATING INSTRUCTIONS contd THERAPY SCREEN Return to previous screen Ta...

Страница 10: ...ive pressure increases to the desired setting This option is especially useful for patients who may experience pain and discomfort during initial pull down and release of the foam especially during in...

Страница 11: ...the feature is used The lockout feature is available from all screen menus example shown is the Utilities Screen To Lock Touchscreen Press the Lock symbol for 3 seconds to disable the touchscreen user...

Страница 12: ...ing the foam mostly intact An alternative is to cut a 2 cm diameter hole into the drape before you lay it down on the foam Either process of cutting the drape will work Note Always cut a 2cm hole in t...

Страница 13: ...in place 3 Verify that both clamps are open 4 Turn therapy ON Canister Removal 1 Turn therapy off 2 Close clamps on canister and dressing tubing 3 Twist T R A C Connector C to disconnect canister tubi...

Страница 14: ...ated These include All tubing and related connectors and clamps Canister V A C ATS dressing and drape Hand and eye protection should be used when handling any body fluids or waste Properly dispose of...

Страница 15: ...minutes which cancels if leak is sealed After an additional 2 minutes a full alarm is sounded and after 5 minutes therapy is turned off Pat around drape to check for leaks If leak is identified patch...

Страница 16: ...V A C ATS unit should be wiped weekly with either a diluted solution of bleach 50ml in 5 liters or mild disinfectant The cloth should be damp not dripping to avoid getting excess fluid anywhere on th...

Страница 17: ...aintenance Manual 13 CLEANING SCREEN 4 Wipe the screen with a clean dry cloth If necessary use a slightly damp cloth and wipe dry 5 Follow the instructions on the screen to exit back to the Home Scree...

Страница 18: ...pending on the settings Average time to recharge battery approximately 4 hours fast charge to reach 85 capacity approximately 10 hours to reach full charge Low battery alarm One tick mark within the b...

Страница 19: ...canister that has a tubing cap fitted If a Battery Exhausted alarm sounds in less than 2 hours the battery pack should be replaced The battery should be changed at 28 months intervals regardless of t...

Страница 20: ...t into the spigot Push firmly upwards to ensure a positive engagement of the filter The filter should be changed in accordance with the Periodic Maintenance schedule Identify the next due date of chan...

Страница 21: ...ery from the charger board 5 4 Unscrew the Battery Retaining Clip and withdraw the battery from the unit 5 5 Remove the battery from the metal clip and replace with a new pack 5 6 Ensure that the lead...

Страница 22: ...chnical Bulletin for detailed instructions 7 0 CONTROLLER BOARD REPLACEMENT 7 1 Remove the Front Housing 7 2 Disconnect the battery 7 3 Remove the Display Touch Screen 7 4 Disconnect the Tubing from t...

Страница 23: ...Chassis plate including the Display and Controller Board by removing the screws on both sides of the front plate 9 6 Disconnect the Charger Board Live and Neutral wires from the IEC Mains Inlet Socket...

Страница 24: ...11 5 Remove the six screws holding the Chassis Plate to the Rear Housing and withdraw the Chassis Plate 11 6 Place the Chassis Plate on its back and unscrew the four screws holding the pump in place...

Страница 25: ...8 Remove the IEC switch as described in section 19 13 9 Re assemble the unit in the new Rear Housing by reversing the above procedure 14 0 IV POLE CLAMP REPLACEMENT 14 1 Remove the Front Housing 14 2...

Страница 26: ...f the Manifold 17 4 Disconnect the tubing from the top spigot of the Valve 17 5 Disconnect the tube from the top of the Bellows Lever 17 6 Re assemble the unit by reversing the above procedure NOTE Th...

Страница 27: ...e Chassis into the Rear Housing Move the Chassis to the left to allow access to the switch 19 5 Disconnect the Brown and Blue wires from the connector terminals 19 6 Disconnect the switch wires 19 7 O...

Страница 28: ...cut the L E D wires in order to remove the Switch Protector A new L E D lead will need to be fitted to the new Switch Protector 20 9 Fit the IEC lead and replacement Switch protector into the rear ho...

Страница 29: ...d software on the PC 2 Connect the serial upgrade cable to a free serial port If the port is not COM1 refer to the ReadMe txt file for the correct command syntax to use other serial ports PROCEDURE 1...

Страница 30: ...her than COM1 you will need to use a shortcut with the correct command line syntax as defined in C Program Files Download ReadMe txt Select correct file type ACCESS PORT RESTRICTED USE Certain pages o...

Страница 31: ...unit off and disconnect the serial cable Switch the therapy unit on and press Utilities then About Check that the software version number is now correct NOTE For language upgrade please refer to the...

Страница 32: ...R 7259184 BATTERY RETAINING BRK ASSEMBLY 6243115 SWITCH PROTECTOR 3258420 GREEN L E D WIRE ASSEMBLY 6265390 SWITCH INLET 4268833 CANISTER LATCH 3266221 SCREW M4X12 PAN HEAD CW S PROOF WASHER 7259187 M...

Страница 33: ...tube Operate therapy at 125mmHg turn therapy off Ensure reading drops to 30mmHg in 10 seconds 13 Set therapy hours to zero 14 Check that the Canister Level Sensor operates correctly in the Engineerin...

Страница 34: ...m H x 7 1 18cm D Weight 12 3lbs 5 6kg ELECTRICAL DATA Voltage 100 240 V Frequency 50 60Hz Maximum power consumption 70W ENVIRONMENTAL DATA Storage Conditions Temperature range 4 F 20 C to 140 F 60 C R...

Страница 35: ...ATS system conforms to the following International standards EN 60601 1 1 1990 including A13 1996 CAN CSA C22 2 No 601 1 M90 UL2601 1 1994 1st Edition Amended 1996 EN60601 1 2 1993 Class II Equipment...

Страница 36: ...ssauga Ontario L5S 1ZL Canada Phone 1 905 565 7187 Fax 1 905 565 7270 Outside USA Canada KCI International Inc 8023 Vantage Dr San Antonio TX 78230 USA Phone 1 210 255 6460 Fax 1 210 255 6991 www woun...

Отзывы: