V.A.C.

 ATS Operations and Maintenance Manual 

 

i

 

 

Caution

 

 

Federal law restricts this device to sale or rental by or on the order of a physician. 

 

In order for KCI products to provide safe, reliable and proper performance, the 
following conditions must be adhered too. Failure to comply with these conditions 
will void any applicable warranties. 

 

 

Assembly, operations, extensions, re-adjustments, modifications, or repairs are 
carried out by qualified personnel authorized by KCI. 

 

 

The electrical installation of the room complies with the appropriate national 
electrical wiring standards. 

 

 

The equipment is used in accordance with the accompanying documentation and 
applicable labelling. 

 

 

Technical maintenance for the product is performed by qualified personnel 
authorized by KCI. 

 

Subject to confidentiality protections, satisfactory to KCI, KCI will make available 
upon request circuit wiring diagrams, component part lists, descriptions, calibration 
instructions, or other information which may assist the user’s appropriately qualified 
personnel to repair those parts of the equipment designated by the manufacturer as 
repairable. 

 

Although this equipment conforms to the intent of the directive 89/336/EEC in 
relation to Electromagnetic Compatibility, all electrical equipment may produce 
interference. If interference is suspected, move equipment from sensitive devices or 
contact the manufacturer. 

 

WARRANTY INFORMATION 

 

IN THE UNLIKELY EVENT OF A DEFECT IN MATERIALS OR 

WORKMANSHIP, A LOCAL KCI OFFICE, SUBSIDIARY OR AUTHORIZED 

AGENT WILL REPAIR, REPLACE OR SUPPLY REPLACEMENT PARTS 

UNDER STANDARD WARRANTY TERMS AND CONDITIONS IN EFFECT AT 

TIME OF PURCHASE. WARRANTY TERMS AND CONDITIONS ARE 

SUBJECT TO CHANGE AT ANYTIME WITHOUT NOTICE. WARRANTY 

TERMS AND CONDITIONS ARE IN LIEU OF ALL OTHER WARRANTIES 

EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY 

IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 

PARTICULAR PURPOSE. IN NO EVENT SHALL KCI BE LIABLE FOR 

CONSEQUENTIAL OR INCIDENTAL DAMAGES AND EXPENSES, 

INCLUDING DAMAGES TO PROPERTY, DUE IN WHOLE OR IN PART TO 

THE USE OF THE PRODUCT UNLESS OTHERWISE EXPRESSLY REQUIRED 

BY LAW. 

 

IN THE EVENT OF DEFECT, REPAIR WORK SHOULD BE COMPLETED BY 
RETURNING THE THERAPY UNIT TO A LOCAL KCI OFFICE, SUBSIDIARY 
OR AUTHORIZED AGENT. CONTACT KCI FOR YOUR NEAREST LOCATION.

 

Содержание V.A.C. ATS

Страница 1: ...ormation contained on those designated pages may be used solely to facilitate the proper maintenance and repair of KCI products identified herein If these terms are unacceptable immediately remove tho...

Страница 2: ...s of the equipment designated by the manufacturer as repairable Although this equipment conforms to the intent of the directive 89 336 EEC in relation to Electromagnetic Compatibility all electrical e...

Страница 3: ...tinuous or Intermittent Therapy 6 Intensity Level 6 Lockout Feature 7 Applying the Dressing 8 Canister Installation Removal 9 Disposal of Used Dressings and Canisters 10 Alarms 11 Canister full 11 Tub...

Страница 4: ...V A C ATS Operations and Maintenance Manual iii Specifications 30 Explanation of Symbols Used 31 Ordering Information 32 Contact addresses 32...

Страница 5: ...r organs Precautions Always Follow Universal Precautions Precautions should be taken with patients exhibiting active bleeding difficult wound hemostasis or who are on anticoagulants When placing the V...

Страница 6: ...und Consider placing a single layer wide meshed non adherent dressing prior to foam placement DISCOMFORT If patient complains of discomfort throughout therapy consider changing to white PVA Versa Foam...

Страница 7: ...y switches to battery power when AC mains power is removed Extended Pump Life Linear brushless pump with increased life expectancy Intensity Setting The speed at which the target pressure setting is a...

Страница 8: ...upright position CAUTION The IV Pole Clamp should only be used on poles that are in excess of 2 2cm 9 diameter and are securely attached to a bed frame or a stable stand To ensure stability of the the...

Страница 9: ...therapy levels between 50 and 200mmHg as per physician order The therapy unit is set at a standard negative pressure of 125mmHg OPERATING INSTRUCTIONS contd THERAPY SCREEN Return to previous screen Ta...

Страница 10: ...ive pressure increases to the desired setting This option is especially useful for patients who may experience pain and discomfort during initial pull down and release of the foam especially during in...

Страница 11: ...the feature is used The lockout feature is available from all screen menus example shown is the Utilities Screen To Lock Touchscreen Press the Lock symbol for 3 seconds to disable the touchscreen user...

Страница 12: ...ing the foam mostly intact An alternative is to cut a 2 cm diameter hole into the drape before you lay it down on the foam Either process of cutting the drape will work Note Always cut a 2cm hole in t...

Страница 13: ...in place 3 Verify that both clamps are open 4 Turn therapy ON Canister Removal 1 Turn therapy off 2 Close clamps on canister and dressing tubing 3 Twist T R A C Connector C to disconnect canister tubi...

Страница 14: ...ated These include All tubing and related connectors and clamps Canister V A C ATS dressing and drape Hand and eye protection should be used when handling any body fluids or waste Properly dispose of...

Страница 15: ...minutes which cancels if leak is sealed After an additional 2 minutes a full alarm is sounded and after 5 minutes therapy is turned off Pat around drape to check for leaks If leak is identified patch...

Страница 16: ...V A C ATS unit should be wiped weekly with either a diluted solution of bleach 50ml in 5 liters or mild disinfectant The cloth should be damp not dripping to avoid getting excess fluid anywhere on th...

Страница 17: ...aintenance Manual 13 CLEANING SCREEN 4 Wipe the screen with a clean dry cloth If necessary use a slightly damp cloth and wipe dry 5 Follow the instructions on the screen to exit back to the Home Scree...

Страница 18: ...pending on the settings Average time to recharge battery approximately 4 hours fast charge to reach 85 capacity approximately 10 hours to reach full charge Low battery alarm One tick mark within the b...

Страница 19: ...canister that has a tubing cap fitted If a Battery Exhausted alarm sounds in less than 2 hours the battery pack should be replaced The battery should be changed at 28 months intervals regardless of t...

Страница 20: ...t into the spigot Push firmly upwards to ensure a positive engagement of the filter The filter should be changed in accordance with the Periodic Maintenance schedule Identify the next due date of chan...

Страница 21: ...ery from the charger board 5 4 Unscrew the Battery Retaining Clip and withdraw the battery from the unit 5 5 Remove the battery from the metal clip and replace with a new pack 5 6 Ensure that the lead...

Страница 22: ...chnical Bulletin for detailed instructions 7 0 CONTROLLER BOARD REPLACEMENT 7 1 Remove the Front Housing 7 2 Disconnect the battery 7 3 Remove the Display Touch Screen 7 4 Disconnect the Tubing from t...

Страница 23: ...Chassis plate including the Display and Controller Board by removing the screws on both sides of the front plate 9 6 Disconnect the Charger Board Live and Neutral wires from the IEC Mains Inlet Socket...

Страница 24: ...11 5 Remove the six screws holding the Chassis Plate to the Rear Housing and withdraw the Chassis Plate 11 6 Place the Chassis Plate on its back and unscrew the four screws holding the pump in place...

Страница 25: ...8 Remove the IEC switch as described in section 19 13 9 Re assemble the unit in the new Rear Housing by reversing the above procedure 14 0 IV POLE CLAMP REPLACEMENT 14 1 Remove the Front Housing 14 2...

Страница 26: ...f the Manifold 17 4 Disconnect the tubing from the top spigot of the Valve 17 5 Disconnect the tube from the top of the Bellows Lever 17 6 Re assemble the unit by reversing the above procedure NOTE Th...

Страница 27: ...e Chassis into the Rear Housing Move the Chassis to the left to allow access to the switch 19 5 Disconnect the Brown and Blue wires from the connector terminals 19 6 Disconnect the switch wires 19 7 O...

Страница 28: ...cut the L E D wires in order to remove the Switch Protector A new L E D lead will need to be fitted to the new Switch Protector 20 9 Fit the IEC lead and replacement Switch protector into the rear ho...

Страница 29: ...d software on the PC 2 Connect the serial upgrade cable to a free serial port If the port is not COM1 refer to the ReadMe txt file for the correct command syntax to use other serial ports PROCEDURE 1...

Страница 30: ...her than COM1 you will need to use a shortcut with the correct command line syntax as defined in C Program Files Download ReadMe txt Select correct file type ACCESS PORT RESTRICTED USE Certain pages o...

Страница 31: ...unit off and disconnect the serial cable Switch the therapy unit on and press Utilities then About Check that the software version number is now correct NOTE For language upgrade please refer to the...

Страница 32: ...R 7259184 BATTERY RETAINING BRK ASSEMBLY 6243115 SWITCH PROTECTOR 3258420 GREEN L E D WIRE ASSEMBLY 6265390 SWITCH INLET 4268833 CANISTER LATCH 3266221 SCREW M4X12 PAN HEAD CW S PROOF WASHER 7259187 M...

Страница 33: ...tube Operate therapy at 125mmHg turn therapy off Ensure reading drops to 30mmHg in 10 seconds 13 Set therapy hours to zero 14 Check that the Canister Level Sensor operates correctly in the Engineerin...

Страница 34: ...m H x 7 1 18cm D Weight 12 3lbs 5 6kg ELECTRICAL DATA Voltage 100 240 V Frequency 50 60Hz Maximum power consumption 70W ENVIRONMENTAL DATA Storage Conditions Temperature range 4 F 20 C to 140 F 60 C R...

Страница 35: ...ATS system conforms to the following International standards EN 60601 1 1 1990 including A13 1996 CAN CSA C22 2 No 601 1 M90 UL2601 1 1994 1st Edition Amended 1996 EN60601 1 2 1993 Class II Equipment...

Страница 36: ...ssauga Ontario L5S 1ZL Canada Phone 1 905 565 7187 Fax 1 905 565 7270 Outside USA Canada KCI International Inc 8023 Vantage Dr San Antonio TX 78230 USA Phone 1 210 255 6460 Fax 1 210 255 6991 www woun...