11. System messages
ERROR MESSAGES
After the error has been eliminated, all error messages must be acknowledged by pressing
START
on the interior control panel.
No.
Status message
Description
Remedy
01
Excess temperature
bimetal
Bimetal switch triggers.
Check the air-intake/air-exhaust system. Let the
device cool down.
02
Maximum tanning time!
Enabling signal from coin-box system
comes in longer than the time value
approved under “Maximum tanning
time” (voltage remains connected)
Disconnect from the coin-box system.
03
Excess temperature
exhaust fan!
Bimetal switch in the fan triggers.
Make sure the fan runs freely. Check the air-
intake/air-exhaust system. Let the device cool
down.
12
KBL7 Hardware error
Input-Controller
Mainboard defective.
Contact your Customer Service.
13
Maximum write cycle
flash memory reached
Maximum write cycle flash memory
reached.
Contact your Customer Service.
14
Error! SD card read error
(CRC fault)
Update via SD card failed (CRC fault). SD card check / replace.
15
Error! no access to the
SD card
Update via SD card failed (access
error).
SD card check / replace
17
Parameter storage not
found, please connect
and restart
Parameter storage not found, please
connect and restart.
Check connector parameter storage. If neces-
sary replace parameter storage.
18
Parameter storage no
valid serial number
Parameter storage no valid serial
number.
Contact your Customer Service.
19
CAN-BUS: Interior dis-
play V1 is incompatible
CAN-BUS operators incompatible.
Use CAN-BUS operaters V2.
20
CAN-BUS: preSelec-
tion display V1 is
incompatible
21
CAN-BUS: audio module
full V1 is incompatible
22
CAN-BUS: RGB module
V1 ist incompatible
23
Parameter storage write
error
Parameter storage write error.
Check connector parameter storage. If neces-
sary replace parameter storage.
24
Parameter storage read
error
Parameter storage read error.
Check connector parameter storage. If neces-
sary replace parameter storage.
25
Frequency detection:
detection failed!
Frequency detection failed.
Restart the controller. Contact your Customer
Service after the third unsuccessful restart.
26
Frequency detection:
power supply connection
faulty (connector X6/E6)!
Frequency detection failed. No mains
voltage.
Check mainboard connector X6/E6.
28
Excess Temperature
Device is running at temperature limit
Let the device cool down. If the error repeats,
contact your customer service.
29
Excess Temperature
Device exceeds the temperature limit
Let the device cool down. If the error repeats,
contact your customer service.
O p e r a t i n g I n s t r u c t i o n s
|
KBL Tower beautyShaper
38
Содержание beautyShaper
Страница 1: ...OPERATING INSTRUCTIONS BEAUTY SYSTEM beautyShaper Tower ...
Страница 2: ......
Страница 44: ...Remarks O p e r a t i n g I n s t r u c t i o n s KBL Tower beautyShaper 44 ...
Страница 45: ...Remarks O p e r a t i n g I n s t r u c t i o n s KBL Tower beautyShaper 45 ...
Страница 46: ...Remarks O p e r a t i n g I n s t r u c t i o n s KBL Tower beautyShaper 46 ...
Страница 47: ......
Страница 48: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...