Guidance and Manufacturer’s Declaration – Electromagnetic Immunity to Interference
The device is intended for use in the electromagnetic environment specified below. The studio operator of the
device should assure that it is used in such an environment.
Immunity tests
IEC 60601-
Test level
Compliance level
Electromagnetic environment
- Guidance
Electrostatic discharge accord-
ing to IEC 61000-4-2
± 8 kV
contact discharge
± 15 kV
air discharge
+/- 8 kV
contact discharge
+/- 15 kV
air discharge
Floors should be made of wood or concrete
or be covered with ceramic tiles. If floors are
covered with synthetic material, the relative
humidity needs to be at least 30 %.
Fast transient electrical distur-
bances/bursts according to IEC
61000-4-4
± 2 kV
for power-supply lines
± 1 kV
for input and output lines
± 2 kV
for power-supply lines
± 1 kV
for input and output lines
Mains power quality should be that of a typi-
cal industrial or hospital environment.
Surge voltages (surges)
according to IEC 61000-4-5
± 1 kV
differential mode voltage
± 2 kV
common mode voltage
± 1 kV
differential mode voltage
± 2 kV
common mode voltage
Mains power quality should be that of a typi-
cal industrial or hospital environment.
Voltage dips, short interrup-
tions and voltage variations
on power-supply input lines
according to IEC 61000-4-11
Dips
0% for 1 cycle
70% for 25/30 cycles
Interrupts
0% for 250/300 cycles
Dips
0% for 1 cycle
70% for 25/30 cycles
Interrupts
0% for 250/300 cycles
Mains power quality should be that of a typi-
cal industrial or hospital environment.
If the studio operator of the device requires
continuous operation of the device even in
the event of interruptions of the power sup-
ply, it is recommended that the device is
powered by an uninterrupted power supply
unit.
Power-frequency (50/60 Hz)
magnetic field according to IEC
61000-4-8
30 A/m
30 A/m
Power-frequency magnetic fields should be
at levels characteristic of a typical location in
a typical industrial or hospital environment.
Содержание beautyShaper
Страница 1: ...OPERATING INSTRUCTIONS BEAUTY SYSTEM beautyShaper Tower ...
Страница 2: ......
Страница 44: ...Remarks O p e r a t i n g I n s t r u c t i o n s KBL Tower beautyShaper 44 ...
Страница 45: ...Remarks O p e r a t i n g I n s t r u c t i o n s KBL Tower beautyShaper 45 ...
Страница 46: ...Remarks O p e r a t i n g I n s t r u c t i o n s KBL Tower beautyShaper 46 ...
Страница 47: ......
Страница 48: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...