5.1 Class I ME equipment
WARNING
Risk of electric shock
To avoid the risk of electric shock, this
equipment must only be connected to a
supply mains with protective earth.
5.3 Connecting the mains voltage
DANGER
Live parts
Risk of death or fatal injury due to electric
shock when touching live parts.
• Switch neutral
• Secure against reconnection
• Check for neutrality
• Ground and short-circuit
• Cover or shield any adjacent live parts or
components
Both the power supply and the related connection
work must comply with national standards and local
regulations. The connection work and replacement
of the power supply cord must only be performed
by qualified, trained and authorized service techni-
cians. The connection to the 3 x 220 V mains must
be protected by maximum over current protection.
For Canada a Class-A ground fault circuit interrupter
(GFCI) has to be used. Further information can be
found in chapter “Technical data”.
CONNECTION REQUIREMENTS
The electrical installation must be equipped with
a freely accessible all-pole disconnecting device in
accordance with the overvoltage category III. (Master
switch with clearly marked on/off settings e.g.
“O” and “I” or additional indicator light). The
master switch shall be fitted externally on the side of
the tanning booth, so the operator can access it at
any time, even when the tanning device is in opera-
tion. This means that for full separation each pole
must have a contact gap according to the condi-
tions of the overvoltage category III. The device shall
be capable of being locked in the off-position and
shall comply with IEC 60447. A supply main switch
must not be incorporated in the power supply cord.
A Class-A ground fault circuit interrupter (GFCI) has
to be used for Canada. Should the operation of the
tanning device cause any interference in the pow-
er supply network, e.g. with ripple-control systems
(TRA), consult your power supply company to have
corresponding blocking elements (audio frequency
suppressors) installed.
WIRING FOR 3-PHASE OPERATION
3-Phase Operation
(3 x 220V / 60Hz)
GND L1 L2 L3
ⓐ
5. Connections
O p e r a t i n g I n s t r u c t i o n s
|
KBL 4800 alpha
19
Содержание 4800 alpha
Страница 1: ...OPERATING INSTRUCTIONS TANNING DEVICE ...
Страница 2: ......
Страница 57: ...Remarks O p e r a t i n g I n s t r u c t i o n s KBL 4800 alpha 57 ...
Страница 58: ...Remarks O p e r a t i n g I n s t r u c t i o n s KBL 4800 alpha 58 ...
Страница 59: ......
Страница 60: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...