V6R VRF 50Hz
Part 2 - Out
door Unit Engineering Da
ta
Mini Amazon III Series
73
Table 2-7.7: KMF-100 DVN4 heating capacity (continued)
Combination (%)
(Capacity index)
Outdoor temperature
(°C DB)
Indoor temperature(°C WB)
16.00
18.00
20.00
21.00
22.00
24.00
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
°C DB
°C WB
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
110%
-13.7
-15
7.63
2.13
7.60
2.17
7.57
2.22
7.57
2.16
7.57
2.21
7.54
2.26
-11.8
-13
7.74
2.16
7.71
2.20
7.71
2.25
7.69
2.19
7.69
2.23
7.66
2.29
-9.8
-11
7.86
2.16
7.83
2.20
7.83
2.25
7.80
2.23
7.80
2.26
7.77
2.32
-9.5
-10
7.91
2.18
7.91
2.23
7.89
2.27
7.86
2.23
7.86
2.29
7.83
2.34
-8.5
-9.1
7.97
2.20
7.94
2.25
7.94
2.30
7.91
2.26
7.91
2.31
7.89
2.37
-7
-7.6
8.06
2.23
8.03
2.27
8.03
2.32
8.00
2.29
8.00
2.34
7.97
2.37
-5
-5.6
8.69
2.26
8.66
2.30
8.63
2.35
8.63
2.31
8.63
2.35
8.37
2.35
-3
-3.7
8.80
2.27
8.77
2.32
8.74
2.37
8.74
2.33
8.74
2.38
8.37
2.31
0
-0.7
8.97
2.33
8.94
2.38
8.94
2.42
8.91
2.35
8.91
2.40
8.37
2.27
3
2.2
9.80
2.43
9.80
2.48
9.77
2.53
9.51
2.44
9.14
2.42
8.37
2.25
5
4.1
11.43
2.66
10.66
2.65
9.91
2.47
9.51
2.40
9.14
2.36
8.37
2.25
7
6
11.43
2.56
10.66
2.49
9.91
2.34
9.51
2.28
9.14
2.25
8.37
2.19
9
7.9
11.43
2.44
10.66
2.36
9.91
2.26
9.51
2.22
9.14
2.20
8.37
2.15
11
9.8
11.43
2.35
10.66
2.27
9.91
2.20
9.51
2.14
9.14
2.13
8.37
2.08
13
11.8
11.43
2.28
10.66
2.20
9.91
2.13
9.51
2.08
9.14
2.06
8.37
2.01
15
13.7
11.43
2.22
10.66
2.13
9.91
2.06
9.51
2.01
9.14
1.99
8.37
1.94
100%
-13.7
-15
7.71
2.53
7.69
2.56
7.69
2.59
7.66
2.60
7.66
2.62
7.63
2.55
-11.8
-13
7.83
2.54
7.80
2.57
7.80
2.59
7.77
2.61
7.77
2.62
7.63
2.52
-9.8
-11
7.89
2.54
7.89
2.57
7.86
2.60
7.86
2.61
7.83
2.62
7.63
2.52
-9.5
-10
7.94
2.54
7.91
2.57
7.91
2.60
7.89
2.61
7.89
2.63
7.63
2.50
-8.5
-9.1
8.03
2.55
8.03
2.57
8.00
2.61
7.97
2.61
7.97
2.63
7.63
2.46
-7
-7.6
8.66
2.55
8.63
2.57
8.63
2.66
8.60
2.71
8.31
2.58
7.63
2.45
-5
-5.6
8.77
2.55
8.74
2.57
8.74
2.60
8.66
2.63
8.31
2.50
7.63
2.38
-3
-3.7
8.94
2.56
8.91
2.58
8.91
2.52
8.66
2.48
8.31
2.42
7.63
2.31
0
-0.7
9.17
2.56
9.69
2.58
9.00
2.45
8.66
2.37
8.31
2.30
7.63
2.20
3
2.2
9.77
2.51
9.69
2.51
9.00
2.38
8.66
2.25
8.31
2.17
7.63
2.10
5
4.1
10.37
2.47
9.69
2.39
9.00
2.26
8.66
2.15
8.31
2.08
7.63
2.00
7
6
10.37
2.44
9.69
2.27
9.00
2.12
8.66
2.04
8.31
1.99
7.63
1.92
9
7.9
10.37
2.30
9.69
2.15
9.00
2.06
8.66
1.99
8.31
1.93
7.63
1.85
11
9.8
10.37
2.15
9.69
2.02
9.00
1.99
8.66
1.91
8.31
1.86
7.63
1.78
13
11.8
10.37
2.02
9.69
1.97
9.00
1.92
8.66
1.84
8.31
1.80
7.63
1.72
15
13.7
10.37
1.92
9.69
1.88
9.00
1.84
8.66
1.77
8.31
1.73
7.63
1.65
Abbreviations:
CR: Combination ratio
TC: Total capacity (kW)
PI: Power input (comp outdoor fan motor) (kW)
Notes:
1. Shaded cells are tested under our standard condition.
2. Avoid running the outdoor unit when outdoor air temperature is below -15 degrees in heating mode.
3. The above table shows the average value of conditions may operate.
4. It is recommended to connect less than 130%.
Содержание KMF-100 DVN4
Страница 140: ......