6
WARNING
•
The appliance disconnection must be incorporated with an all-pole disconnection device in the
fixed wiring in accordance with the wiring rules.
•
Any person who is involved with working on or breaking into a refrigerant circuit should hold a
current valid certificate from an industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an industry recognized assessment
specification.
•
Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be carried out
under the supervision of the person competent in the use of flammable refrigerants.
•
The appliance shall be stored to prevent mechanical damage from occurring.
•
Keep ventilation openings clear of obstruction.
NOTE:
The following information are required for the units adopt R32 Refrigerant.
•
The appliance shall be stored in a room without continuously operating ignition sources
(for example: open flames, an operating gas appliance or an operating electric heater).
•
Do not pierce or burn.
•
Be aware that the refrigerants may not contain an odor.
•
Compliance with national gas regulations shall be observed.
•
Appliance shall be stored in a well-ventilated area where the room size corresponds to the room
area as specified for operation.
•
Appliance shall be installed, operated and stored in a room with a floor area larger than X m²,
installation of pipe-work shall be kept to a minimum X m² (Please see the following form).
The appliance shall not be installed in an unventilated space, if that space is smaller than X m²
(Please see the following form). Spaces where refrigerant pipes shall be compliance with
national gas regulations.
Model
(Btu/h)
Amount of refrigerant
to be charged (kg)
maximum installation
height (m)
Minimum room
area (m²)
≤30000
≤2.048
2.2m
4
30000-48000
2.048-3.0
2.2m
4
>48000
>3.0
2.2m
5