23
Filter cleaning
²
In terms of the air filter set in air inlet direct.
²
Anti-clockwise unscrew the air inlet ring.
²
Take out the filter and clean it completely.
²
Remount it to the unit.
Restart after a long term stop
When the unit is restarted after a long term stop (include trail running), it is normal that outlet
water is unclean. Keep the tap on and the water will be clean soon.
12. Trouble shooting
Error phenomenon shooting
Error phenomenon
Possible reason
Solution
Cold water tapped out and
display screen extinguished.
Bad connection of power supply wire.
Connection well
Setting water temperature too low.
Setting water temperature higher.
Temperature sensor broken.
PCB of indicator broken.
Replace the sensor or PCB.
No hot water tapped out.
Public water supply ceased.
Waiting for water supply recover.
Water inlet pressure too low.
Waiting for the pressure increase.
Water inlet valve closed.
Open water inlet valve.
Water leakage
Hydraulic pipeline joints are not sealed well. Check and reseal all joints.