-25-
控制面板
(FD683)
無畫面
The control panel
(FD683) is blank.
檢查連接線
(FD682)
是否鬆脫
Check if the
connection wires
FD682 are loose.
請重新連接後
再測試
Please reconnect
and test.
檢查電控箱內所有連接
線是否鬆脫
Check if the wires in the
electronic controller box
are loose?
請重新連接後
再測試
Please reconnect
and test.
檢查電源供應器
FD677
輸入電壓
是否正常(
AC220V
)
Check if the power supplier
FD677 input voltage
(AC220V) is regular?
請確認電源開關與電
源插座
Please check the
power switch and the
power plug.
Yes
Yes
No
No
No
No
Yes
Yes
步進馬達無動作
The stepping motor
driver is no signal.
檢查馬達
FD674
連接線是否鬆脫
Check if the motor
FD674 connection
wire is loose?
請重新連接後
再測試
Please reconnect and
test.
檢查電控箱內所有
連接線是否鬆脫
Check if there any
connection wire in the
electronic control box is
loose?
請重新連接後
再測試
Please reconnect and test.
檢查送帶機構是否輕順
Check if the feeding achine
is smooth and light?
請確認調整送帶機構
Please check and adjust the
feeding machine.
Yes
Yes
No
No
No
Yes
檢查電源供應器
FD677
輸出電壓是否正常(
DC 24V
)
Check if the power supplier FD677 output voltage
(DC24V) is regular?
請確認步進馬達阻抗值是否正確
Please confirm if the impedance value in the
stepping motor driver is accurate?
Yes
更換電源供應器(
FD677
)
Change the power supplier (FD677).
No
更換步進馬達(
FD674
)
Change the stepping motor driver (FD674).
No
Yes
Содержание Siruba LF-D6
Страница 1: ...LF D6 使用說明書與零件圖 INSTRUCTION BOOK PARTS LIST ...
Страница 2: ......
Страница 12: ...組合圖 COMBINATION 控制組 1 Control Box 1 控制組 2 Control Box 2 控制組 3 Control Box 3 踏板開關 Pedal Switch 8 ...
Страница 14: ... 10 接管圖 WIRINGDIAGRAM ...
Страница 33: ... 29 ...
Страница 34: ... 30 ...
Страница 35: ... 31 ...
Страница 36: ... 32 ...
Страница 37: ... 33 ...
Страница 38: ... 34 ...
Страница 39: ... 35 桌板圖 TABLE CUT OUT OF 747S T5 ...
Страница 40: ......
Страница 41: ......