23
SAT
Button
LNB voltage
[0]
0 V
[1]
12 V
[2]
14 V
[3]
18 V
[5]
5 V
[8]
22 kHz
For checking purposes the LED right from
[LNB CNTRL]
button is
on when the power supply is turned on.
Press the
[LNB BATT]
button to indicate the power consumption
of the connected LNB on the display.
The additionally connectable 22 kHz signal will superimpose the
LNB voltage. It is necessary e.g. for the change-over of multi-feed
systems or high band/low band LNB’s.
Command overview for LNB voltage
[LNB CNTRL]
Call the LNB menu
[0]
...
[5]
Select LNB voltage
[<]
or
[>]
Change LNB voltage in 0.1 V intervals
[8]
22 kHz signal on/off
[LNB CNTRL]
Exit the LNB menu
Example
Calling up 14 V LNB voltage:
Press
[LNB CNTRL] [2]
LC display:
• LNB voltage: 14 V
• Power consumption: 150 mA
By pressing the
[<]
or
[>]
button you can change the LNB voltage
in 0.1 V intervals.
Press
[LNB CNTRL]
to exit the LNB menu.
Note
The following voltages can be
called up via button command: