6
battery guard from the remote to activate the battery
connection.
2. The RGB control box is ready to mount
next to your Kasco C-25, C-85, C-95 or 3phase
fountain control box. (Mount a minimum of 5ft from
water). Using two exterior grade wood screws: one
for the top and one for the bottom hanger. The RGB
control will hang from the screws. You only need to
tighten the top screw to prevent the box from lifting
off the screws. Mount close enough to plug the power
cord into your Kasco C-25 panel.
NOTE: DO NOT PLUG IN AT THIS TIME!
3. Once mounted, you are ready to connect
the RGB light kit power cord to the field terminal
connections in the RGB control box.
Connect:
White to white
Green to Green
Red to Red
Black to Black
Connect light kit power cord wires to this terminal
block.
4. The control box is now ready to plug into
your Kasco C-25 fountain control box. Plug into the
Light receptacle in the C-25. This will allow the C-25
to control the lights with the fountain. To energize the
C-25 light receptacle you will need to cover the photo-
eye of the C-25. Refer to your C-25 instructions.
If you have a Kasco C-85, C-95 or 3phase control
panel, you will need to hardwire the RGB controller
power cord to the light terminals in your fountain
control panel. Refer to your fountain owner’s manual
for connection information.
RGB control panel installation & operating
instructions
Important Safety:
Please read and follow these important safety and
handling instructions for your Kasco equipment.
Following these instructions will help ensure your
safety and the quality performance of your equipment.
• Under NO circumstances should anyone enter the
water with the electrical equipment plugged in and/
or in operation. All Kasco equipment is designed
and built for use in water, and fountain control
panels are available with GFCI protection. However,
it is NEVER recommended to enter the water with
the equipment in operation.
• Kasco’s Submersible Light Kits are intended for use
with a Listed control panel having a GFCI protected
receptacle, or field wiring terminals & disconnect
switch, or a timer with disconnect
• for use with a GFCI receptacle. They are intended to
be mounted on a floating fountain or aerator
• for use in a natural or man-made body of water to
comply with NEC Article 682.
• Kasco’s Submersible Light Kits have not been
evaluated for use in swimming pools, spas or
• stationary fountains.
• The power connection for the RGB light controller
is 120Vac and MUST be plugged into a GFCI
protected receptacle or GFCI protected field
terminal connection.
• Caution should be used when dealing with any
electrical and/or moving equipment.
• NEVER run the unit out of water. It could create a
dangerous situation for the operator.
Refer to your fountain/Aerator owner’s manual for
complete installation, operation and safety instructions
for your installation.
Inspect the control panel for any damage.
Report damage to your distributor or Kasco.
Installation:
1. Open the control box and remove the
operating instruction sheet, Remote control, and
battery. Insert the battery into the remote control.
If the battery is already inserted, remove the plastic