MODEL: C95
DISPLAY AERATOR CONTROL WITH TIME SWITCH, GFCB,
LIGHTNING ARRESTOR AND 15 AMP GFCI LIGHTING RECEPTACLE
SUITABLE FOR USE WITH SUBMERSIBLE LIGHTS
IN RAINPROOF (TYPE 3R) ENCLOSURE SUITABLE FOR INDOOR OR OUTDOOR USE
40 AMP. MAX PER LEG 120/240 VOLT SINGLE PHASE (THREE WIRE) AC
PUMP CIRCUIT: 24 FLA, 144 LRA, 240 Vac, LIGHT CIRCUIT: 120 Vac - 15 amp Max.
MIN. 75˚ C SUPPLY CONDUCTORS
PHOTO CONTROL RATINGS: 120 VAC 50/60 HZ. 1800W TUNGSTEN, 8.3A BALLAST
LIGHTNING ARRESTOR RATINGS: 120/240 VAC; MCOV 250 VAC
TIME SWITCH OPERATING INSTRUCTIONS
1. TO SET “ON” AND “OFF” TIMES:
Hold TRIPPERS against edge of
CLOCK-DIAL, pointing to time (AM or
PM) when
ON
and
OFF
operations are
desired. Tighten tripper screws firmly.
2. TO SET TIME-OF-DAY:
Pull CLOCK-DIAL outward. Turn in
either direction and align the exact time-
of-day on the CLOCK-DIAL (the time
now, when switch is being put into
operation) to the pointer.
-DO NOT MOVE POINTER-
•
TO OPERATE SWITCH MANUALLY:
Move MANUAL-LEVER
below left or right as indicated by arrows. This will not affect the
next operation.
•
FOR MORE THAN ONE DAILY ON-OFF OPERATION:
Place additional tripper pairs on CLOCK-DIAL (order
156T1978A).
•
IN CASE OF POWER FAILURE:
Reset CLOCK-DIAL to proper
time of day. See step 2 above.
ON
TRIPPER
TIME
POINTER
TIME
DIAL
OFF
TRIPPER
MANUAL
LEVER
Wiring information-Copper
Conductors
Wire
Terminal
Size
Tightening Torque
AWG
Lb-In
14
20
12
20
10
20
8
25
6
35
4
45
3
50
2
50
IMPORTANT:
This control panel must be installed
according to the National Electrical Code (including
article 680) and local code requirements. The main
lugs and neutral main are suitable for No. 14 to 2 AWG
COPPER
conductors. Follow gauge selection table and
corresponding terminal screw tightening torque require-
ments below. An additional branch circuit protector (20 Amp
max) may be installed in the unused position for use as an
auxiliary circuit. Use only Square D HOM Series circuit
breakers for addition or replacement (do not exceed rat-
ings on wiring diagram). Follow Manufacturers instructions
for testing of ground fault circuit breakers (GFCB). This
panel is equipped with a 120V AC - 15 amp duplex GFCI
receptacle for connecting a 120V AC light kit or an external
low voltage transformer for lighting. The Pump Terminal Bar
is controlled by the timer only. The Lighting GFCI outlet is
controlled by the timer and photoelectric circuit. Refer to the
instructions provided with your light kit. After wiring, install
front panel over wiring compartment.
KEEP DOOR CLOSED AT ALL TIMES.
KASCO MARINE, INC.,
800 Deere Road
Prescott, WI 54021-1241
•
Phone (715) 262-4488
UL508
UL1563
NEC 680
LR3730
T30004R31
PUMP CIRCUIT
158PS13206
30 A
OPEN (20 A)