E5
Empty
wastewa-
ter.
O
O
Insert the wastewater con-
tainer properly and lock it.
Empty the wastewater res-
ervoir.
Check the float in the tank
for mobility.
E8
Filling pro-
cedure
please wait
O
Note
Information only appears
upon the initial filling.
E10
Seclect
rinsing pro-
gramme
O
Note
Information appears after
operation with detergent.
No steam operation possi-
ble.
E11
Heating
O
X
Note
Information only appears
upon the initial filling.
E12
Service
fault: E12
O
O
Check the connector plug
"hand tool" on the device
for proper seating.
The connector plug "hand
tool" on the device must be
completely dry.
E13
Service
fault: E13
O
O
Check the connector plug
"hand tool" on the device
for proper seating.
The connector plug "hand
tool" on the device must be
completely dry.
Actuate reset button µc-
card.
E14
Service
fault: E14
O
X
Note
Steam boiler should be
descaled.
See chapter:
Descaling steam boiler
E15
Service
fault: E15
O
O
Note
Steam boiler must be
descaled.
See chapter:
Descaling steam boiler
E16
Service
fault: 16
O
O
O
Check fan for soiling or
damage.
Check the connector.
Check plug contacts on the
power electronics (power
card).
Check ribbon cable that
connects the power card
with μc-card.
If defective, exchange μc-
card.
Note
Further tests see:
Table of measurement values
Error
codes
Display
Cause
Correction
Fault
Cause
Correction
Display on, pump without function
Performance electronics
Check the fuse.
Replace defective fuse.
Fuse 6.3A (slow-blow)