English
5.906-590.0 Rev. 01 (05/17)
39
1 Screws
2 Carrier
Unscrew the screws.
Unplug the protective conductor cable.
Open the carrier.
ABGL Uninstall / install appliance cover on the left side
ADAT Open / close carrier
1 Hose water pump in the back
2 Rubber bearing
3 Hose water pump at the top
4 Nut
5 Hose
6 Water pump
7 Boiler pump
8 Electric connectors
Separate the electric connectors.
Remove the hose of the water pump in the back.
Remove the water pump from the rubber bearing at the
back.
Remove the hose of the water pump at the top.
Loosen nut and pull off the hose.
Remove the water pump from the rubber bearing at the
front.
ABGL Uninstall / install appliance cover on the left side
ADAT Open / close carrier
The procedure conforms to the task:
ADWP Uninstall / install water pump
ABGL Uninstall / install appliance cover on the left side
ADAT Open / close carrier
1 Holder solenoid valves
2 Screws
3 Hose
4 Solenoid valve
Unscrew the screws.
Remove the holder for the solenoid valves.
Disconnect the connectors.
Pull the hose off at the front and back.
Remove solenoid valves.
ADWP Uninstall / install water pump
ADKP Uninstall / install boiler pump