46
English
5.906-590.0 Rev. 01 (05/17)
몇
WARNING
Prior to all work on the appliance, switch off the appliance
and pull the power plug.
Allow the device to cool down prior to performing any ser-
vice tasks.
Relieve the high pressure system of all pressure prior to all
work on the appliance and the accessories.
Wear protective clothing (gloves, goggles, apron).
Note
When handling descalers, the specific safety information
must be observed.
All components used for the descaling process must be
acid-resistant.
Required components:
1 Reset button
Insert the appliance plug into the mains socket.
Switch the rotary switch into the "0/OFF" position.
Remove the waste water container.
Remove the fresh water container.
Switch handwheel in position "Apply hot water".
Switch rotary switch in position "Operating mode:
Steam/hot water/cold water/suction operation.
The current software version is shown on the display.
Switch handwheel to position operating mode: "cold
water mode".
The message "Service mode activated" appears on the
display.
Depressurize the appliance via the steam switch.
Unscrew the screws on the control panel.
Remove the control panel.
Press the Reset switch.
Reinstall the operating panel.
The service lamp must be out.
Remove detergent container.
Remove steam suction pipe.
ABGL Uninstall / install appliance cover on the left side
ADSO Uninstall / install probe water level
1 Covers
2 Nuts
3 Covering plate
Remove covers.
Loosen the nuts.
Swivel the cover plate to the side.
050 Maintenance and inspection
Descaling steam boiler
Descaling set
2.840-035.0
Lime-dissolving acid
RM 101
6.295-398.0
Drain screw
6.304-182.0
Loctite 620
6.284-001.0
Locking paint
6.282-014.0
Covers
6.368-403.0
Superglue Drei Bond
6.869-007.0
Resetting the service indicator
Parts of the system