27
Maintenance
CUDA 7248 Operator’s Manual 9.801-712.0 - AA
Power
ON
Power
OFF
Power
OFF
Power
OFF
Power
OFF
Measure Voltage Across
L1, L2 and L3 Terminals
on Junction Box
Electrical Panel is OK,
C h e ck M a i n Po w e r
Disconnect
Remove Primary Fuses;
Measure the Resistance
of Each
Fuse is Blown; Replace
Blown Fuse
R e m ove S e c o n d a r y
F u s e ; M e a s u r e t h e
Resistance
S e c o n d a r y F u s e i s
Blown; Replace Fuse
Remove Heater Fuses;
Measure the Resistance
of Each
One of the Heater Fuses
is Blown; Replace the
Blown Fuse
Remove Pump Fuses;
Measure the Resistance
of Each
One of the Pump Fuses
is Blown; Replace the
Blown Fuse
E l e c t r i c a l Pa n e l i s
OK. Refer to Testing
Individual Components
Within specs listed on machine ID tag
approximately 0 Ohms
approximately 0 Ohms
approximately 0 Ohms
approximately 0 Ohms
None
GR
OUND
To Safety
Switch
To Transfer
Pump
To Heating
Element
Transformer
Heater
Contactor
Pump
Contactor
Heater Fuses
Pump
Fuses
Pump
Overload
Secondary
Fuse
Primary
Fuses
Junction Box
Grounding
Lug
To Side
Control Box
Содержание CUDA 7248
Страница 2: ...2 CUDA 7248 Operator s Manual 9 801 712 0 AA Machine Data Label...
Страница 33: ...33 Parts Parts CUDA 7248 1 043 516 0 1 043 517 0 1 043 518 0 CUDA 7248 Operator s Manual 9 801 712 0 AA...
Страница 37: ...37 CUDA 7248 Operator s Manual 9 801 712 0 AA Notes...
Страница 56: ...9 801 712 0 Printed in U S A...