ROUTINE MAINTENANCE 
 

Clean  transmitter  regularly  with 

damp 

cloth 

and 

mild 

detergent. 

 

Inspect electrical wiring for wear 

points or other damage.  Repair 
as required. 

 

Inspect  all  connections  for 
looseness  or  corrosion.    Tighten 

and/or "seal" as necessary. 

 

MAINTENANCE 
PRECAUTIONS 
 

When  performing  any inspection 

or  maintenance  work  on  the 

remote  system,  always  exercise 
care to prevent injury to yourself 

and  others  or  damage  to  the 

equipment.    The  following  are 

general 

precautions, 

which 

should  be  closely  followed  in 

carrying  out  any  maintenance 

work. 

Do  not  have  hydraulic  power 

available  to  the  valves  when 
performing electrical tests. 

 

Never  operate  or  test  any 
function  if  any  person  is  in  an 

area  where  they  could  be  hurt 

by being  hit  or  squeezed by  the 
hydraulic equipment. 

 

Turn 

power 

off 

before 

connecting 

or 

disconnecting 

valve  coils  or  other  electrical 

loads. 

 

Содержание MICRO

Страница 1: ...MICRO RADIO REMOTE CONTROL SYSTEM INSTALLATION AND OPERATION MANUAL NORTHERN AG 3A4261EJ doc September 27 2021 BF...

Страница 2: ...SYSTEM TROUBLESHOOTING USING OPTIONAL GATE 9 ACCESSING THE CONTROL PANEL 10 DIAGNOSTICS 10 CALIBRATION 11 HISTOGRAM 12 SOFTWARE UPDATE 13 GATE CONFIGURATION 14 GATE UPDATE 15 WIRING 17 ROUTINE MAINTEN...

Страница 3: ...wiring harnesses and Gate interface tools The transmitter is equipped with pushbuttons for the various functions This transmitter runs on a 3 7V rechargeable battery The system s radio receiver has bo...

Страница 4: ...OOM 2 Keep holding until the green and red LEDs start blinking together slowly Release buttons 3 Press one of the following buttons for desired sleep time a ROLL RIGHT 15 minutes b ROLL LEFT 30 minute...

Страница 5: ...system is designed to operate with a unique radio ID code and RF channel sequence Each receiver is programmed to respond only to the transmitter with the correct ID code RF channel sequence for which...

Страница 6: ...same ID code as the original transmitter A If this feature is desired use the following procedure 1 Make sure transmitters and receivers are off 2 On transmitter A press and hold POWER button for more...

Страница 7: ...DC cigarette charger into the USB port Red and green LED indicators near the top of the transmitter indicate the status of the charger A red LED indicates that the battery is charging and a green LED...

Страница 8: ...er module use the mounting holes provided on the enclosure to attach it in a vertical manner with the wires facing down Please take extra caution not to damage internal components while installing It...

Страница 9: ...ting the ground directly to the BATTERY terminal is preferred for optimal performance All connections must be properly insulated to protect against shorts Seal all connections with a non conductive si...

Страница 10: ...smart phones pads or personal computers It supports Google Chrome Internet Explorer Firefox and IOS Safari and allows user to configure diagnose and troubleshoot the system The GATE s POWER LED will s...

Страница 11: ...under the name of NORTHERN3A426 should be available at this point Connect to the network the password is 3A4266A1 5 Once the connection is established open a web browser on your device Kar Tech recom...

Страница 12: ...to be active or ON Diagnostics CALIBRATION To change the configuration of the unit tap the Calibration icon Calibration The password to gain access to the calibration screens is 1262 To adjust a prop...

Страница 13: ...Ramp Down Time in seconds to go from Max PWM to zero e Frequency Dither frequency to valves in Hz Change affects all outputs 3 Enter the new value in the new value box 4 Tap the Save button to send t...

Страница 14: ...ATE is not a precision measurement instrument There may be delays Histogram Page SOFTWARE UPDATE Use the Choose File button to select new software on your device with which to program the receiver Kar...

Страница 15: ...is hidden and it would require manual connection to the network If Enable Multiple Connections is selected multiple connections up to 4 devices could be connected to the GATE However only one of the c...

Страница 16: ...on the GATE will be deleted Gate Update Page 1 Select LOAD 2 Disconnect then reconnect to NORTHERN3A426 network 3 Press HOME button 4 Screen below should be shown 5 Press Gate Software Update 6 Using...

Страница 17: ...MICRO REMOTE 16 precision measurement instrument There may be some delays...

Страница 18: ...14GA GXL GROUND WHITE 14GA GXL ROLLOVER LEFT PWM OUTPUT WHITE 14GA GXL ROLLOVER RIGHT PWM OUTPUT BLUE 18GA GXL IDLE LOW PWM OUTPUT BROWN 18GA GXL IDLE HIGH PWM OUTPUT WHITE 14GA GXL BOOM OUTPUT PIN D...

Страница 19: ...rk on the remote system always exercise care to prevent injury to yourself and others or damage to the equipment The following are general precautions which should be closely followed in carrying out...

Страница 20: ...next section provides basic operator level troubleshooting for the MICRO REMOTE system If after following these instructions the system still does not function contact your KAR TECH representative fo...

Страница 21: ...ufficient cooling Certain functions do not work 1 Check the wiring and connections from the receiver control module to the control module to the valve coil for the particular function that does not wo...

Страница 22: ...MICRO REMOTE 21 and possible obstructions 4 Check the hydraulic system...

Страница 23: ...ter is off Transmitter went to sleep mode Interference in RF communication link 2 System voltage is below 11V 12V system 4 7 Short or open load coil on output 8 Switch or joystick on transmitter is no...

Страница 24: ...e receiver Return the units for service Note For operation with negative ground systems only WARNING The MICRO REMOTE must be operated in compliance with all applicable safety regulations rules and pr...

Страница 25: ...MICRO REMOTE 24 TRANSMITTER PICTORIAL 2 75 0 58 1 63 BOOM ON OFF Roll RIGHT Roll LEFT Northern Ag Idle LOW Idle HIGH...

Страница 26: ...ate heat that must be dissipated The published amps rating can only be fully achieved if adequate cooling is provided Mount the controller so that the enclosure makes contact with a metallic surface c...

Страница 27: ...torage temperature 40 C to 100 C RF Frequency 902 928 MHz RF Transmit power EIRP 10 mW LCD display operating range if equipped 20 C to 70 C Vibration 3G to 200Hz Shock 50G NEMA 12 RECEIVER Power suppl...

Страница 28: ...f and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Отзывы: