background image

MICRO REMOTE 

 

6

changed.    This  will  unclone  the 

transmitters.    If  this  is  desired, 
use the following procedure: 

 

1.

 

 Make sure the receiver and 
transmitters are OFF 

2.

 

Press  and  hold  buttons 

ROLL  LEFT,  IDLE  HIGH, 
BOOM,  and  POWER  until 

the  LEDs  start  to  toggle.  

Release buttons 

3.

 

Press  any  button  again  to 
select a new ID 

4.

 

Uncloning complete 

5.

 

Use 

transmitter 

and 

receiver 

synchronization 

procedure above to link the 

uncloned  transmitter  to 
new receivers 

 
BATTERY CHARGING 
 

The  battery  can  be  charged  by 

plugging  the  AC  wall  charger  or 
DC  cigarette  charger  into  the 

USB  port.  Red  and  green  LED 

indicators  near  the  top  of  the 

transmitter indicate the status of 

the charger: A red LED indicates 
that  the  battery  is  charging  and 

a  green  LED  indicates  that  the 

battery is fully charged.  
 

IMPORTANT BATTERY INFO 

When  the  battery  is  new,  the 
run-time  of  the  transmitter  will 

be  shorter  until  it  has  gone 

through  the  drain/charge  cycle 

several  times.  After  this  point, 
the  unit’s  current  drain  should 

allow  at  least  20  hours  of  run-

time  before  a  recharge  is 
needed. 

 

The 

temperature 

that 

the 

transmitter battery is exposed to 

affects  performance  and  useful 

life.  It  is  strongly  recommended 
you  keep  within  the  following 

limits: 

A.

 

Charging: -4 to +86

B.

 

Operating: -20 to +122

Содержание MICRO

Страница 1: ...MICRO RADIO REMOTE CONTROL SYSTEM INSTALLATION AND OPERATION MANUAL NORTHERN AG 3A4261EJ doc September 27 2021 BF...

Страница 2: ...SYSTEM TROUBLESHOOTING USING OPTIONAL GATE 9 ACCESSING THE CONTROL PANEL 10 DIAGNOSTICS 10 CALIBRATION 11 HISTOGRAM 12 SOFTWARE UPDATE 13 GATE CONFIGURATION 14 GATE UPDATE 15 WIRING 17 ROUTINE MAINTEN...

Страница 3: ...wiring harnesses and Gate interface tools The transmitter is equipped with pushbuttons for the various functions This transmitter runs on a 3 7V rechargeable battery The system s radio receiver has bo...

Страница 4: ...OOM 2 Keep holding until the green and red LEDs start blinking together slowly Release buttons 3 Press one of the following buttons for desired sleep time a ROLL RIGHT 15 minutes b ROLL LEFT 30 minute...

Страница 5: ...system is designed to operate with a unique radio ID code and RF channel sequence Each receiver is programmed to respond only to the transmitter with the correct ID code RF channel sequence for which...

Страница 6: ...same ID code as the original transmitter A If this feature is desired use the following procedure 1 Make sure transmitters and receivers are off 2 On transmitter A press and hold POWER button for more...

Страница 7: ...DC cigarette charger into the USB port Red and green LED indicators near the top of the transmitter indicate the status of the charger A red LED indicates that the battery is charging and a green LED...

Страница 8: ...er module use the mounting holes provided on the enclosure to attach it in a vertical manner with the wires facing down Please take extra caution not to damage internal components while installing It...

Страница 9: ...ting the ground directly to the BATTERY terminal is preferred for optimal performance All connections must be properly insulated to protect against shorts Seal all connections with a non conductive si...

Страница 10: ...smart phones pads or personal computers It supports Google Chrome Internet Explorer Firefox and IOS Safari and allows user to configure diagnose and troubleshoot the system The GATE s POWER LED will s...

Страница 11: ...under the name of NORTHERN3A426 should be available at this point Connect to the network the password is 3A4266A1 5 Once the connection is established open a web browser on your device Kar Tech recom...

Страница 12: ...to be active or ON Diagnostics CALIBRATION To change the configuration of the unit tap the Calibration icon Calibration The password to gain access to the calibration screens is 1262 To adjust a prop...

Страница 13: ...Ramp Down Time in seconds to go from Max PWM to zero e Frequency Dither frequency to valves in Hz Change affects all outputs 3 Enter the new value in the new value box 4 Tap the Save button to send t...

Страница 14: ...ATE is not a precision measurement instrument There may be delays Histogram Page SOFTWARE UPDATE Use the Choose File button to select new software on your device with which to program the receiver Kar...

Страница 15: ...is hidden and it would require manual connection to the network If Enable Multiple Connections is selected multiple connections up to 4 devices could be connected to the GATE However only one of the c...

Страница 16: ...on the GATE will be deleted Gate Update Page 1 Select LOAD 2 Disconnect then reconnect to NORTHERN3A426 network 3 Press HOME button 4 Screen below should be shown 5 Press Gate Software Update 6 Using...

Страница 17: ...MICRO REMOTE 16 precision measurement instrument There may be some delays...

Страница 18: ...14GA GXL GROUND WHITE 14GA GXL ROLLOVER LEFT PWM OUTPUT WHITE 14GA GXL ROLLOVER RIGHT PWM OUTPUT BLUE 18GA GXL IDLE LOW PWM OUTPUT BROWN 18GA GXL IDLE HIGH PWM OUTPUT WHITE 14GA GXL BOOM OUTPUT PIN D...

Страница 19: ...rk on the remote system always exercise care to prevent injury to yourself and others or damage to the equipment The following are general precautions which should be closely followed in carrying out...

Страница 20: ...next section provides basic operator level troubleshooting for the MICRO REMOTE system If after following these instructions the system still does not function contact your KAR TECH representative fo...

Страница 21: ...ufficient cooling Certain functions do not work 1 Check the wiring and connections from the receiver control module to the control module to the valve coil for the particular function that does not wo...

Страница 22: ...MICRO REMOTE 21 and possible obstructions 4 Check the hydraulic system...

Страница 23: ...ter is off Transmitter went to sleep mode Interference in RF communication link 2 System voltage is below 11V 12V system 4 7 Short or open load coil on output 8 Switch or joystick on transmitter is no...

Страница 24: ...e receiver Return the units for service Note For operation with negative ground systems only WARNING The MICRO REMOTE must be operated in compliance with all applicable safety regulations rules and pr...

Страница 25: ...MICRO REMOTE 24 TRANSMITTER PICTORIAL 2 75 0 58 1 63 BOOM ON OFF Roll RIGHT Roll LEFT Northern Ag Idle LOW Idle HIGH...

Страница 26: ...ate heat that must be dissipated The published amps rating can only be fully achieved if adequate cooling is provided Mount the controller so that the enclosure makes contact with a metallic surface c...

Страница 27: ...torage temperature 40 C to 100 C RF Frequency 902 928 MHz RF Transmit power EIRP 10 mW LCD display operating range if equipped 20 C to 70 C Vibration 3G to 200Hz Shock 50G NEMA 12 RECEIVER Power suppl...

Страница 28: ...f and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Отзывы: