than that for which it is intended.

• personal protective equipment should be a personal issue item.

• before use ensure about the compatibility of items of equipment assembled into a fall arrest system. 

Periodically check connecting and adjusting of the equipment components to avoid accidental loose-

ning or disconnecting of the components.

• it is forbidden to use combinations of items of equipment in which the safe function of any one item 

is affected by or interferes with the safe function of another.

• before each use of personal protective equipment it is obligatory to carry out a pre-use check of 

the equipment, to ensure that it is in a serviceable condition and operates correctly before it is used.

• during pre-use check it is necessary to inspect all elements of the equipment in respect of any 

damages, excessive wear, corrosion, abrasion, cutting or incorrect acting, especially take into con-

sideration:

-in full body harnesses and belts - buckles, adjusting elements, attaching points, webbings, seams, 

loops;

- in energy absorbers - attaching loops, webbing, seams, casing, connectors;

- in textile lanyards or lifelines or guidelines - rope, loops, thimbles, connectors, adjusting element, 

splices;

- in steel lanyards or lifelines or guidelines - cable, wires, clips, ferrules, loops, thimbles, connectors, 

adjusting elements;

- in retractable fall arresters - cable or webbing, retractor and brake proper acting, casing, energy 

absorber, connector;

- in guided type fall arresters - body of the fall arrester, sliding function, locking gear acting, rivets and 

screws, connector, energy absorber;

- in metalic components (connectors, hooks, anchors) - main body, rivets, gate, locking gear acting.

• after every 12 months of utilization, personal protective equipment must be withdrawn from use to 

carry out periodical detailed inspection. The periodic inspection must be carried out by a competent 

person for periodic inspection. The periodic inspection can be carried out also by the manufacturer 

or his authorized representative.

• in case of some types of the complex equipment e.g. some types of retractable fall arresters 

the annual inspection can be carried out only by the manufacturer or his authorized representative.

• regular periodic inspections are the essential for equipment maintenance and the safety of the 

users which depends upon the continued efficiency and durability of the equipment.

• during periodic inspection it is necessary to check the legibility of the equipment marking. Don’t use 

the equipment with the illegible marking.

• it is essential for the safety of the user that if the product is re-sold outside the original country of 

destination the reseller shall provide instructions for use, for maintenance, for periodic examination 

and for repair in language of the country in which the product is to be used.

• personal protective equipment must be withdrawn from use immediately when any doubt arise 

about its condition for safe use and not used again until confirmed in writing by equipment manu-

facturer or his representative after carried out the detailed inspection.

• personal protective equipment must be withdrawn from use immediately and destroyed (or another 

procedures shall be introduced according detailed instruction from equipment manual) when it have 

been used to arrest a fall.

• a full body harness (conforming to EN 361) is the only acceptable body holding device that can be 

used, in a fall arrest system.

• in full body harness use only attachment points marked with a capital letter "A" to attach a fall 

arrest system.

• the anchor device or anchor point for the fall arrest system should always be positioned, and the 

work carried out in such a way, as to minimise both the potential for falls and potential fall distance. 

The anchor device/point should be placed above the position of the user . The shape and construction 

of  the anchor device/point shall not allowed to self-acting disconnection of the equipment. Minimal 

static strength of the anchor device/point is 12 kN. It is recommended to use certified and marked 

structural anchor point complied with EN795

Содержание 27956

Страница 1: ...zioni e informazioni del produttore Manufacturer s instruction and information Instructions et informations du fabricant Herstelleranweisung und Informationen Instrucci n e informaci n del fabricante...

Страница 2: ...orma Europea h Logo CE e numero dell ente notificato che effettua il controllo della produzione del dispositivo i Attenzione leggere il manuale prima dell utilizzo j Nome del produttore o del distribu...

Страница 3: ...ose other than that for which it is intended personal protective equipment should be a personal issue item before use ensure about the compatibility of items of equipment assembled into a fall arrest...

Страница 4: ...cro assorbitore di energia connettore nei dispositivi anticaduta di tipo guidato corpo del dispositivo anticaduta funzione di scorrimento azione del meccanismo di bloccaggio rivetti e viti connettore...

Страница 5: ...onfezione ad es borsa in tessuto a prova di umidit o di stagnola o custodie in acciaio o plastica per proteggerlo da danni o umidit l apparecchiatura pu essere pulita senza causare effetti negativi su...

Страница 6: ...deve essere compilata prima del primo utilizzo del dispositivo Ogni informazione inerente il dispositivo quale ispezione periodica riparazione motivo del ritiro del dispositivo devono essere annotati...

Страница 7: ...standard h CE mark and number of the notified body controlling manufacturing of the equipment i Caution read and understand the instruction manual before use l Identification of the harness manufactu...

Страница 8: ...facturer or his representative after carried out the detailed inspection personal protective equipment must be withdrawn from use immediately and destroyed or another procedures shall be introduced ac...

Страница 9: ...lso by the manufacturer or his authorized representative in case of some types of the complex equipment e g some types of retractable fall arresters the annual inspection can be carried out only by th...

Страница 10: ...y hand or in a machine and rinse in water For energy absorbers use only a damp cloth to wipe away dirt It s forbidden to immerse energy absorbers into the water Plastic parts can be cleaned only with...

Страница 11: ...on responsible in the user organisation for protective equipment Any information about the equipment like periodic inspections repairs reasons of equipment s withdrawal from use shall be noted into th...

Страница 12: ...de dispositif b Num ro de r f rence c Longueur du dispositif d Mois et ann e de fabrication e Num ro de s rie du dispositif f La charge nominale maximale du dispositif g Num ro ann e de la norme euro...

Страница 13: ...r procedures shall be introduced according detailed instruction from equipment manual when it have been used to arrest a fall a full body harness conforming to EN 361 is the only acceptable body holdi...

Страница 14: ...tichutes r tractables c ble ou sangle fonctionnement correct r tracteur et frein enve loppe absorbeur d nergie connecteur pour les antichutes de type guid corps du dispositif antichute fonction coulis...

Страница 15: ...xtile ou un sac en aluminium r sistant l humidit ou en bo tes en acier ou en plastique pour le prot ger contre tout dommage et contre l humidit l quipement peut tre nettoy sans causer d effets ind sir...

Страница 16: ...enseignement relatif l quipement tel que les contr les p riodiques les r parations les raisons pour lesquelles il a t mis hors d usage doivent tre inscrits sur la carte d identit par une personne comp...

Страница 17: ...Jahr der Europ ischen Norm h CE Kennzeichnung und Nummer der f r die Ger tehers tellungskontrolle notifizierten Stelle i Achtung Lesen und verstehen Sie vor dem Gebrauch die Bedienungsanleitung j Iden...

Страница 18: ...nd destroyed or another procedures shall be introduced according detailed instruction from equipment manual when it have been used to arrest a fall a full body harness conforming to EN 361 is the only...

Страница 19: ...as Verbindungselement bei mitlaufenden Auffangger ten den Korpus des Auffangger tes die Gleitfunktion das Fun ktionieren des Blockademechanismus die Nieten und Schrauben das Verbindungselement den Fal...

Страница 20: ...n elektrische Leitf higkeit Die pers nliche Schutzausr stung muss in der Verpackung transportiert werden z B in einem Beutel aus feuchtigkeitsbest ndigem Stoff oder in einem Folienbeutel oder in Kiste...

Страница 21: ...ie Ausr stung wie wiederkehrende Inspektionen Reparaturen Gr nde f r die Au erbetriebnahme des Ger tes sind von einer kompetenten Person der Nutzerorganisation in die Ger tekarte einzutragen Die Ger t...

Страница 22: ...Marca CE y n mero del organismo i Atenci n leer y comprender las instrucciones antes del uso j Identificaci n del fabricante o el distribuidor del arn s st be compatible with oof textile or foil bag o...

Страница 23: ...sentative after carried out the detailed inspection personal protective equipment must be withdrawn from use immediately and destroyed or another procedures shall be introduced according detailed inst...

Страница 24: ...a retractor y correcto funcionamiento del freno carcasa absorbedor de energ a conector en dispositivos antica das deslizantes cuerpo del dispositivo de retenci n deslizamiento correcto funcionamiento...

Страница 25: ...ca el equipo de protecci n individual debe ser transportado en su embalaje por ejemplo una bolsa de tejido resistente a la humedad o una bolsa de papel metalizado o una caja de acero o pl stico para p...

Страница 26: ...rganizaci n del usuario Cualquier informaci n sobre el equipo como revisiones peri dicas reparaciones motivos de la retirada del uso del equipo deber ser anotada en la hoja de identificaci n por una p...

Страница 27: ...NOTE...

Страница 28: ...IT Morganti Spa Via S Egidio 12 23900 LECCO Italy Tel 39 0341 215411 Fax 39 0341 215400 kapriol kapriol com www kapriol com Ago 2019 Rev 2 art 27956 8 019190 279563...

Отзывы: