H50U Glass&Dish Washer installation and operation manual
- 7 -
valves or solenoid valves. The manufacturer takes no responsibility over any damages
and related cost caused by foreign bodies in manual or solenoid valve.
Gently pull the inlet hose to confirm fastening, turn on the faucet after installation, check if
there is leakage. Before each operation, please check if the taps and water inlet are
installed firmly, to prevent disconnection.
Water supply
Incoming Water Supply Requirements
Temperature
Pressure
(
Dynamic
)
℃
℉
Kpa Kg/cm
2
With 3KW Booster
Heater
40
~
60
104
~
140
196
~
490 2
~
5
With 6KW Booster
Heater
10
~
60
50
~
140 196
~
490 2
~
5
Drain Connection
Connect the drain pipe below wash tank to a suitable drain. If a grease trap is required by
local code, there should be a minimum flow capacity of 95.5 liters per minute (21 gallons
per minute).
Note:
Please test the incoming water pressure after installation, if the flow pressure is
lower than 2kg/cm
2
, please install booster pumps (provided by others); If the static
pressure is higher than 5kg/cm
2
, please install a pressure reducing valve (provided by
others).