H50U Glass&Dish Washer installation and operation manual
- 8 -
4 Operation
Testing
Water inlet hose
Please clean the inlet hose before connection, clean all the filters after initial operation
Plumbing connections and flow pressure
Check if the inlet hose is connected firmly, as looseness and leakage may happen in
transporting and carrying. Related non-standard flow pressure can lead to faults of the
machine.
Electrical Connection
Fasten all terminals in the control box, check if all of them are tightened, visual test for
all the electrical equipment if they are in good condition, (for example: switches, cables,
motor shell, etc.), and test all the functions of power switch.
Check the interior
Make sure that there are no irrelevant parts inside the machine (for example: hanging
cloth, screws, nuts, tools, packaging materials, etc.).
Operating of Control Panel
Basic requirements:
a
.
Working Temp.
:
0
~
50
℃
;
b
.
Humidity
:
40
~
93%
;
c
.
Anti-interference
:
IEC—801standard
d
.
MTBF
:
≥
10,000 hours
;
e
.
Voltage
:
AC380V/220V
(
+10%
,
-15%
)
50Hz±1Hz
;
f
.
Relay Output: 220V/2A
;
Control Panel
Warning
1. Disconnect the 380/220V AC power before installation, maintenance or
replacement, or it may be dangerous!
2. Installation and maintenance personnel must be trained electrical technicians!