6 Trouble Shooting
Trouble Shooting Techniques
This section may help you avoid a service call. If a symptom persists after the
possible causes have been checked, please contact our service center or local authorized
service office.
Symptom
P o s si b l e C a u s e s & S u g g e s t ed
Solution
No machine
operation
1. Open the door and close it.
2. Blown fuse or tripped circuit breaker at power supply.
3. Check if fuse at control circuit is blown.
Long wash
cycle
1. Water temperature in booster is too low
2. Water in booster is below high level sensor; please examine line strainer and
solenoid valve.
Dishes not
clean
1. Wash pump rotating in wrong direction.
2. Insufficient water pressure due to obstruction at pump intake screen.
Disconnect power supply, drain wash tank and check.
3. Low water temperature. Insufficient warm-up time. Check thermostat and
heater.
4. Incorrect detergent dispensing. Contact your detergent representative.
5. Excessive mineral deposits through wash and rinse system. Deliming may
be necessary.
Spotting
silverware,
glasses, and
dishes
1. Racks are improperly loaded.
2. Incorrect rinse water temperature.
3. Low water pressure due to pump obstruction
4. Excessively hardness of water.
5. Incorrect detergent for water type.
6. Incorrect rinse aid for water type.
7. Incorrect concentration of detergent and rinse aid
Inadequate
rinse
1, Dirty line strainer causing reduced water flow. Turn off water supply,
disconnect water inlet hose and solenoid valve. Reassemble the strainer after
remove and clean it
2, Low water pressure at water supply
Leaking valve
Foreign material prevents proper valve operation. Note: It's critical for a check
after installation, for compound or metal shavings of water pipe may lodge at the
valve. Shut off water supply. Unscrew and take out bonnet from valve body.
Clean the valve and reassemble.
No or slow fill
1. Dirty line strainer causing reduced water flow. Turn off water supply,
disconnect water inlet hose and solenoid valve. Reassemble the strainer after
remove and clean it
2. Low water pressure at water supply