H50U Glass&Dish Washer installation and operation manual
- 6 -
The dishwasher must be level before any connections are made. Turn the leveling feet
as required to level the machine and adjust to the desired height.
A hood or vent may be required in order to meet local codes. The lowest ventilation
capacity should be 2.8m
3
/min(supplied by others).
Check before installation
Check if there are cracks on the appearance, looseness or damages in all
connections, electrical circuit, and other parts.
Electrical Connections
Please reach the control box for power connection, correctly connect power cords of
different color to power supply according to their descriptions and the electrical diagram at
inside of machine panel.
Cable and Switch Selection
(correct selection of the power cords and break switch
is required for power supply )
The selection of power cord and switch, please refer to the table of "Major Technical
Data".
Plumbing connections
Connect the water pipe to the incoming water supply (3/4”NPT internal threads) , Please
thoroughly clean the hands before any installation staff connects water pipe to any manual
Warning
1, Electrical and grounding connections must comply with applicable portions of the
national electrical code and other local codes.
2, Prior to connecting the appliance, ensure that the voltage and the supply fuse
complies with the rating plate and configuration of the mains terminal block within the
appliance.
3, Disconnect the electrical power supply and place a tag at power switch indicating
that you are working on the circuit.
Warning
1, Water connections must comply with the hygiene and safety standards and water
installation regulations.
2, When flow pressure of incoming water is lower than 2Kg/cm
2
, it is better not to use
the machine.Because low water pressure would affect washing efficiency. The
temperature of incoming water should not exceed 65 ° C, and the pressure should not
exceed 5kg/cm
2
.