KANEXPRO
HDMX44-18G
14 |
P a g e
reliable RS232 control.
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
6.3 RS232 Communication Commands
1)
“[“, “]” in the commands are for easy recognition only and not necessary in real
operations. Other symbols including “.”, “,”, “/”, “%”, “;”, “^”. are parts of the
commands.
2)
Feedbacks listed in the column “Feedback Example” are only for reference,
feedbacks may vary according to different operations.
3)
Dial the EDID switcher to “1111” before sending commands pertaining to software
EDID management (with grey background).
6.3.1 System Commands
Command
Function
Feedback Example
/*Type;
Query the model.
XXXXX
/^Version;
Query the version of firmware
VX.X.X
Demo.
Switch to the “demo” mode, convert
input and output in turn like1B1,
1B2, …4B3, 4B4, 1B1… and so
on .The switching interval is 2
seconds.
Demo Mode
AV:01->01
AV:01->02
AV:01->03
AV:01->04
AV:02->01
…
Normal Mode
Undo.
To cancel the current operation.
Undo Ok!
PWON.
Work in normal mode.
PWON
PWOFF.
Enter into standby mode, send the
“
PWON.
” to start.
PWOFF
STANDBY.
Enter into standby mode, press other
buttons or send other commands to
start.)
STANDBY
%9962.
Query the power status
STANDBY/PWOFF/
PWON
%9964.
Query the IP address.
IP:XXX.XXX.X.XXX
%0911.
Reset to factory default.
Factory Default