KANEXPRO
HDMX44-18G
17 |
P a g e
EDIDH[x]B[y].
Input port [y] learns the EDID from
output port [x].
If the EDID data is available and the
audio part supports not only PCM
mode, then force-set it to support
PCM mode only. If the EDID data is
not available, then set it as initialized
EDID data.
EDIDH1B1
EDIDPCM[x].
Set the audio part of input port [x] to
PCM format in EDID database.
EDIDPCM[x]
EDIDG[x].
Get EDID data from output [x] and
display the output port number.
Hexadecimal
EDID
data
and
carriage
return character
EDIDMInit.
Restore the factory default EDID data
for each input.
EDIDMInit.
EDIDM[X]B[Y].
Manually EDID switching. Enable
input [Y] to learn the EDID data of
output [X]. If the EDID data is not
available, then set it as initialized
EDID data.
EDIDM3B1
EDID/[x]/[y].
Set the EDID data of input port [x] to
built-in EDID No. [y]. [y] = 0~11,
correspond to the 12 embedded
EDID data separately.
EDID/[x]/[y]
EDIDUpgrade[x
].
Upgrade EDID data via the RS232
port.
X represents the input port, and x=5
represents all input ports.
When the switcher receives the
command, it will show a message to
prompt you to send EDID file (.bin
file). Operations will be canceled after
10 seconds.
Please send the EDID
file
EDID Upgrade OK!
GetInPortEDID
[X]
Get the EDID data of input [x],
[x]=1~4
%9979.
Get the DIP switcher status
EDID
RS232
GUI
CONTROL 1111