24
11.8.1 Function and Parameter Range
Low start speed:
10-2000mS. The value is bigger, the slow start time is longer. For
those welding tools that are not easy to vibrate, this value can be increased properly.
Phase lock speed
:
high speed, quick speed, medium speed, low speed, phase lock
rate.
Auto-searching
:
disable, enable, 1 time/min, 3 times/min, 5times/min, 7times/min,
9times/min. Auto-tuning without loading, Compensating frequency deviation due
to increased temperature.
Searching amplitude:
0-1%.
Searching bandwidth Min
:
0-13KHz.
Searching bandwidth Max
:
Min-70KHz.
Slow start speed:
10-2000mS. The value is bigger, the shutoff speed is slower.
Protection speed:
1-100Ms.For the responding speed for work protection, the
smaller the value is, the more sensitive of the protection is.
For the occasional protection action, please increase this value.
Peak current:
1-25A.
Peak voltage:
500-4000V.
Impedance limit without load:
15-100
Ω
.
Frequency deviation:
0-99Hz.
11.9 Factory Setting
Click Factory setting to enter into this page, password is: 2005.