9
7.3.4 Input/output control interface (DB25)
7.4 Power Supply Connection Ports/Outer Control Input/Output Ports
Pin
Name
Status
Function description
C1_10
Start
Input ports
US start up (Note 1)
C1_9
AUX_1
In Standard mode: US searching; in Auto
mode, US trigger (Note2)
C1_8
AUX_2
In Standard mode: amplitude
segmentation; in Auto mode: Emergency
stop (Note3)
C1-7
AUX_3
In Standard mode: Shake-off control; in
Auto mode: grounding detection (Note4)
C1_11
COM_OV
Common port for output
C1_2
READY
Output ports
“READY” status output.
C1_3
Mvt
“Hold” status output (Note5)
C1_4
H.F
“US work” status output (Note6)
C1_5
OVL
“Overload” status output (press RESET or
US search to remove it.
C1_6
ERROR
“Error” status output (Note7)