MULTICAL® 402
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
75
11.2
Pulse outputs (CE and CV)
The pulse duration of pulse outputs for energy and volume can be ordered at 32 ms. or 0.1 s. After delivery the
pulse duration can be changed by means of the PC program METERTOOL (see paragraph 14)
The resolution of the pulse outputs always follows the least significant digit of the energy and volume readings
respectively (see CCC-codes, paragraph 3.3.1).
The pulse outputs can be configured under the country code to display one of the following registers per pulse
output:
E1 (Heat energy)
E3 (Cooling energy)
V1 (Volume)
TA2 (Totalized energy or volume)
TA3 (Totalized energy or volume)
The pulse output readings cannot be changed after configuration.
The pulse outputs have been configured with the following default values:
Meter function
Output C (16-17) - CE
Output D (18-19) - CV
Country codes
Verification mode*
E1 and E3**
V1
All
Heat meter
E1
V1
1XX
2XX
4XX
9XX
Heat meter
E1
E3
3XX
Cooling meter
E3
V1
5XX
Heat/cooling meter
E1
E3
6XX
Volume meter
V1
V1
7XX
8XX
*) The pulse outputs are not configurable in verification mode
**) All measured energy is emitted as pulses
The original configuration of the pulse duration (see paragraph 3.7) is maintained. The pulse resolution remains
unchanged both in verification mode and in normal mode.
The pulse resolution follows the display (determined by the CCC-code). For example CCC=119: 1 pulse/kWh and 1
pulse/0.01 m
3
The pulse outputs are designed with darlington optocouplers, which makes them suitable for most signal types.
Please note the polarity when making the connection. See paragraph 2.2 re electrical data of the pulse outputs.
Содержание MULTICAL 402
Страница 1: ...MULTICAL 402 Technical Description...
Страница 2: ...MULTICAL 402 2 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016...
Страница 109: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 109...
Страница 113: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 113...