MULTICAL® 402
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
19
D
a
te
S
ta
m
p
H
e
a
t m
ete
r
DDD=
2
1
0
H
e
a
t m
ete
r
DDD=
4
1
0
C
o
o
li
n
g
m
e
te
r
DDD=
5
1
0
H
e
a
t/
co
o
li
n
g
DDD=
6
1
0
Vo
lu
m
e
/H
e
a
t
DDD=
7
10
V
ol
u
m
e
/C
ool
DDD=
8
10
En
e
rg
y
m
e
te
r
DDD=
9
10
15.0
VA (Input A)
10
10
9
10
4
4
9
15.1
Meter No. VA
10A
10A
9A
10A
4A
4A
9A
15.2
Yearly data
•
10B
10B
9B
10B
4B
4B
9B
15.3
Monthly data
•
10C
10C
9C
10C
4C
4C
9C
16.0
VB (Input B)
11
11
10
11
5
5
10
16.1
Meter No. VB
11A
11A
10A
11A
5A
5A
10A
16.2
Yearly data
•
11B
11B
10B
11B
5B
5B
10B
16.3
Monthly data
•
11C
11C
10C
11C
5C
5C
10C
17.0
TA2
12
12
12
17.1
TL2
12A
12A
18.0
TA3
13
13
13
18.1
TL3
13A
13A
19.0
Info Code
14
14
11
14
6
6
11
19.1
Info event counter
14A
14A
11A
14A
6A
6A
11A
19.2
Info logger (36 latest events)
•
14B
14B
11B
14B
6B
6B
11B
20.0
Customer number (N
o
1+2)
15
15
12
15
7
7
12
20.1
Date
15A
15A
12A
15A
7A
7A
12A
20.2
Hour
15B
15B
12B
15B
7B
7B
12B
20.3
Target date
15C
15C
12C
15C
7C
7C
12C
20.4
Serial no.
(N
o
3)
15D
15D
12D
15D
7D
7D
12D
20.5
Prog. (A-B-CCC)
(N
o
4)
15E
15E
12E
15E
7E
7E
12E
20.6
Config 1 (DDD-EE)
(N
o
5)
15F
15F
12F
15F
7F
7F
12F
20.7
Config 2 (FF-GG-N-PP)
(N
o
6)
15G
15G
12G
15G
7G
7G
12G
20.8
Software edition
(N
o
10)
15H
15H
12H
15H
7H
7H
12H
20.9
Software check sum
(N
o
11)
15I
15I
12I
15I
7I
7I
12I
20.10 Segment test
15J
15J
12J
15J
7J
7J
12J
20.15
M-Bus primary adr.
(N
o
31)
15K
15K
12K
15K
7K
7K
12K
20.16
M-Bus secondary adr.
(N
o
32)
15L
15L
12L
15L
7L
7L
12L
Number of yearly data displayed (1…15)
2
2
2
2
2
2
2
Number of monthly data displayed (1…36)
12
12
12
12
12
12
12
DDD=210 is the ”standard code” of heat meters with meter type 402xxxxxxx2xx. Please contact Kamstrup for
other combinations. A DDD-code can contain max. 103 readings including 4 data logger counts.
A total survey of existing display codes (DDD) appear from a separate document.
Please contact Kamstrup for further details.
PM are indications which only appear in verification mode.
Note: Data reading can collect up to 36 monthly data and up to 15 yearly data. The number of displayed yearly and monthly
data is determined by the DDD-code.
3.4.1
Energy overview
The above-mentioned energy types E1, E3, E8 and E9 are calculated as follows:
Formula
Example of application
Condition
E1=V1(T1-T2)
Heat energy (V1 in flow or return)
T1
>
T2
T1
>
θ
hc
Legal Display/Data/Log
(Forward temperature must be
higher than the limit value)
E3=V1(T2-T1)
Cooling energy (V1 in flow or return)
T2
>
T1
T1
>
θ
hc
Legal Display/Data/Log
(Forward temperature must be
lower than the limit value)
E8=m
3
Used for calculation of average
temperature of forward pipe
x T1
None
Display/Data/Log
E9=m
3
Used for calculation of average
temperature of return pipe
x T2
None
Display/Data/Log
θ
hc
If
θ
is the temperature, at which the meter shifts between heat and cooling measurement. The typical value is
25
°
C, but other values can be supplied as required.
hc
is set at 180
°
C the function is disconnected, e.g. to be used for ”purchase/sales” of heat. See paragraph 7.4
for further information on heat/cooling meters.
Содержание MULTICAL 402
Страница 1: ...MULTICAL 402 Technical Description...
Страница 2: ...MULTICAL 402 2 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016...
Страница 109: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 109...
Страница 113: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 113...