MULTICAL® 402
24
Kamstrup A/S · Technical Description · 5512-742_M1_GB_01.2016
3.7
>PP< Output C and Output D
Pulse outputs for energy (CE) and volume (CV) are available on the following modules (see paragraph 11.1 for
further information on connection):
Type 402-
Data + 2 pulse outputs (CE, CV)
11
M-Bus + 2 pulse outputs (CE, CV)
21
Radio, EU, 434 MHz, Int.+Ext. Ant., NET0 + 2 pulse outputs (CE, CV)
43
Radio, EU, 434 MHz, Int.+Ext. Ant., NET1 + 2 pulse outputs (CE, CV)
45
Reconfiguration between pulse inputs and pulse outputs is not necessary with MULTICAL
®
402. When a module
with pulse outputs is mounted in MULTICAL
®
Pulse durations of 1 ms, 32 ms. or 0.1 s. are available when ordering. After delivery the pulse duration can be
changed by means of the PC program METERTOOL (see paragraph 14)
402, the meter is automatically configured for pulse outputs.
Output C
(CE) Terminal 16-17
Output D
(CV) Terminal 18-19
PP
Pulse duration
94
1 ms.
95
32 ms.
PP=95 is default on delivery
96
0.1 s.
Pulse duration 0.1 s. reduces the battery lifetime.
Please contact Kamstrup for further information
3.8
Configuration during set up of country code
The two last characters of the type number, called the country code, are used to set up the language of the label
text e.g. ”meter in return”, class 2 or 3, indication of approval and verification mark, as well as whether the meter
is to be supplied with fast/slow integration speed, and if info codes are to be deleted automatically when the
error disappears.
Type 402-
Country code
XX
Please contact Kamstrup for further details on available country codes. The available country codes appear from
internal document 5514-169 on Kamstrup’s Intranet.
3.8.1
Integration time and reset type of info codes
Unless otherwise stated in the order the default configuration of MULTICAL
®
402 will include integration (energy
calculation) every 24 seconds as well as automatic reset of info codes when the error disappears.
24 s. integration (default)
4 s. integration
Info codes are reset automatically (default)
Info codes must be reset manually
Содержание MULTICAL 402
Страница 1: ...MULTICAL 402 Technical Description...
Страница 2: ...MULTICAL 402 2 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016...
Страница 109: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 109...
Страница 113: ...MULTICAL 402 Kamstrup A S Technical Description 5512 742_M1_GB_01 2016 113...